background image

 

 

Safety instructions

 

 

Read  this  instruction  manual  in  its  entirety  before  you 
start  operating  the  unit.  Especially  read  through  any 
information  regarding  the  battery  and  recharging 
process to prevent damage to the accumulators.  

 

 

The  equipment  should  only  be  used  by  trained 
operators. 

 

 

The installation of  the working area has to correspond 
to  the  relevant  regulations.  Set  up  the  unit  in  such  a 
way, that the air slits are not blocked and the extracted 
air can escape well. 

 

 

Only switch on the unit, if the handpiece rests secured 
in the handpiece holder, or if you hold it safely in your 
hand. 

 

 

To  avoid  the  risk  of  electrocution  only  connect  the 
device to the mains power supply. 
 

 

If you pull the power plug it will stop the connection to 
the  mains  power  supply.  Set  up  the  unit  so  that  the 
power  plug  is  always  accessible.  The  power  switch 
should also always be easily accessible. 

 

 

Prevent  any  liquids  from  entering  into  the  control  unit, 
since this could damage the electronic elements. 
Clean the outside of the box only with a damped cloth. 
Make sure, that you have unplugged the unit before. 

 

Содержание 0897

Страница 1: ...Manual Xantos Art No 0897 0898 FB 04 280 Rev 1 Art no 0897 0898 ...

Страница 2: ...ctions 3 Cleaning Disinfection 7 Getting to know the unit 8 Before the use 9 Area of application 9 Installation site location 9 Maintenance Care 11 Cleaning the chuck 11 Handling details 12 Troubleshooting 13 Technical data 14 ...

Страница 3: ... extracted air can escape well Only switch on the unit if the handpiece rests secured in the handpiece holder or if you hold it safely in your hand To avoid the risk of electrocution only connect the device to the mains power supply If you pull the power plug it will stop the connection to the mains power supply Set up the unit so that the power plug is always accessible The power switch should al...

Страница 4: ...ction or spray technique Wear a nose and mouth protection Always follow the safety instructions provided by the manufacturer of the materials being formed and used For safety reasons wear goggles during the treatment Ensure that the patient s foot and the handpiece are held firmly in place during the operation To prevent injury work with extreme caution on the foot of the patient and use only ligh...

Страница 5: ...e Before using the equipment assure that the tool can be pushed far enough into the chuck Test this with a dipstick and clean the handpiece if necessary the inserted tool sits properly in the chuck and will not cant jam while clamping it the tool is approved for using it at the max speed see manufacturer s instructions or only use the speed required by the instrument the tool is absolutely dry For...

Страница 6: ...nly to be accomplished by an authorized specialist The mains cable may also only be changed by the manufacturer or an authorized specialist Never remove the housing especially not while the equipment is plugged into the socket since some components are under electric voltage Any unauthorized or improper handling e g trying to repair the unit of the equipment will immediately nullify the guarantee ...

Страница 7: ... capper etc first Then handle the cleaning of the tool according to the instructions of it s manufacturer Remove tissue remains by wiping off the unit with a mildly moistened paper cloth Afterwards clean all surfaces with disinfection cloth e g Mikrozid AF Tücher of Schülke and Mayr The charging unit is only to be cleaned with a dry cloth ...

Страница 8: ...8 Getting to know the unit 1 Speed display 2 LED shines during left rotation 3 Increase speed 4 change directory 5 decrease speed 6 on off button 8 ...

Страница 9: ...Dental technique laboratory Milling trimming and polishing work at plaster casts and models Do not use this unit for dentist purposes i e working directly on the patient Industry Grinding milling and polishing works Installation site location The installation of the workroom must correspond to any regulations according to your country laws Set up the control unit so that the ventilation slits are ...

Страница 10: ...ith a diameter of 2 35 mm this is the diameter usually used for tools in podiatry To open the chuck push the spanner forward with your thumb and leave it there Now insert the tool as far as possible Pull back the knob and the tool will be firmly clamped For security reasons only change the tool if the handpiece is turned off Setting up the speed Hold the handpiece incl tool in your hand or store i...

Страница 11: ...k To assemble the chuck follow the steps in reverse order Make sure that the chuck is opened during the assembly the handpiece button must be in forward position and is firmly applied afterwards Cleaning the chuck Soak the chuck in spirit or a special cleaning liquid for tools Clean the slits and the hole of the chuck with a dry scrubber or brush Rinse the chuck very well and make sure you let it ...

Страница 12: ...when you not working with the handpiece always remove the bur tool from it Always make sure that you do not let the handpiece fall down or exposes it to any shocks The ball bearings and the motor could be damaged by this Only work with tools which are flawless Do not work with tools which are bent or out of balance whose shaft is worn out or are rusty Working with faulty tools will cause a stronge...

Страница 13: ...e if it is bent Chuck is dirty Clean the chuck according to the instructions in the manual Bur does not clamp or does not spin Chuck is not tightened well Tighten the chuck firmly according to the instruction in the manual Knob of the handpiece can not be moved easily Chuck is dirty Clean the chuck according to the instructions in the manual Unit does not work at all Pull out the mains plug to res...

Страница 14: ...n relates are conform to the following standards or normative documents 2014 30 EU directive EMC 2014 35 EU low voltage directive hadewe GmbH Grambartstraße 10 30165 Hannover Germany Symbols Caution Important Note Follow instructions for use I O Unit ON OFF Speed Regulation Up Down Switch to reverse direction LED ON LED is on in reverse direction Direct current Safety fuse Alternating Current Do n...

Страница 15: ......

Страница 16: ...hadewe GmbH Grambartstraße 10 30165 Hannover Germany info hadewe de www hadewe de ...

Отзывы: