Installation
5.52.800.00.01.00
13
6 Installation
Pos: 10.2.1 /1_HADEF/6--MONTAGE/Allgemein/01.APK+800 @ 2\mod_1286346968854_52.docx @ 15820 @ @ 1
Assembly depends on the local environment. The crane must be secured against movement and collapsing.
Do not use the crane structure to step on it.
Pos: 10.3.1 /1_HADEF/6--MONTAGE/Krane/800/01 Grundsätzliches @ 3\mod_1373550078517_52.docx @ 26990 @ @ 1
6.1 General
The beam must be adjusted horizontally and beam supports of the side constructions must be adjusted
vertically.
Pos: 10.3.2 /1_HADEF/6--MONTAGE/Krane/800/02 Gefahren bei Montage @ 3\mod_1373550108641_52.docx @ 26996 @ @ 1
6.1
Dangers during assembly
CAUTION!
The wheels of the side columns must be secured against rolling away.
The side parts must be secured against turning over.
If the wind intensity is 40 km/h or more, the crane must be moved indoors, or fixed stable to the ground.
Pos: 10.3.3 /1_HADEF/6--MONTAGE/Krane/800/03 Montage - Zusammenbau @ 3\mod_1373551796542_52.docx @ 27002 @ @ 1
6.2
Montage – Zusammenbau
Seitenteile (1) und Träger (2) mittels
Schraubensatz (4) verschrauben.
Alle Schrauben mit Drehmomentenschlüssel
gemäß Tabelle anziehen.
Alle Schraubenverbindungen nochmals
kontrollieren.
Hebezeuge nach deren Anleitung montieren.
Bild 3
Pos: 10.3.4 /1_HADEF/6--MONTAGE/Schraubentabellen/Anzugsmomente M6-M33 @ 2\mod_1288088437030_52.docx @ 16583 @ @ 1
6.3
Table of screws
Tighten the screws with tightening moment mentioned in the table
Thread Tightening
moment (Nm) in
property class
8.8 10.9
M 6
10,4
15,3
M 8
25,3
37,2
M 10
51
75
M 12
87
128
M 14
139
205
M 16
214
314
M 18
280
390
M 20
431
615
M 22
530
750
M 24
742
1159
M 27
1000
1400
M 30
1350
1900
M 33
2000
2800
coefficient of friction 0,12 - 0,14
μ
ges
Pos: 10.3.5 /1_HADEF/6--MONTAGE/Krane/800/05 Demontage @ 3\mod_1373553861525_52.docx @ 27012 @ @ 1