HADEF EEE Скачать руководство пользователя страница 17

 

 

 

5.52.707.00.01.02  

 17

 

16 Remedy 

 

Pos: 20.2.1 /1_HADEF/16-ABHILFE/Alle/01.Alle E+P @ 3\mod_1414501384045_52.docx @ 27821 @  @ 1 

 

Problem* Unit 

Cause 

Remedy 

Unit cannot be switched on 

Electric Hoists 

No main power 

Check connection to mains supply

 

Phase sequence not correct (with low voltage control) 

exchange 2 phases 

(see waring note at the plug) 

Hoist motor does not run

 

Electric Hoists 

Fuse burnt out

 

Replace the fuse

 

Defective switching unit in the control button switch

 

Replace the switching unit

 

Interruption in the control cable

 

Check control cable and replace if necessary.

 

Defect of capacitor (only for alternating current 1). 

Replace the capacitor 

Defective coil - mechanic or electric overload

 

Motor must be repaired by a specialist 

If the unit is suitable for explosive atmosphere, the motor 
must be returned to the manufactuerer for repair!*

Pneumatic 

hoists and 

winches 

Operation pressure/ quantity of air is too low 

Check connection to mains supply 

After prolonged standstill 

See maintenance - pneumatic motor 

Hoist motor runs – load is not lifted

 

For motor driven 

chain hoists. 

and winches 

Overload protection is activated - (with overload)

 

Reduce the load to nominal load

 

Overload protection is activated - (with =< nominal 

load)

 

Check settings and reset if necessary

 

No or incorrect power transmission 

Let the unit be repaired by en expert 

For EX-hoists, please clarify with the manufacturer what 
to do!*

 

Hoist motor is running – chain does not lower

 

For motor driven 

chain hoists. 

Blockage due to chain link pointing sideways in the 

feed from the chain container*

 

Check the chain - lubricate if necessary 

and/or select a larger chain container so that the 

chain can be properly arranged before the inlet 

Motor hums and uses excessive current 

 

Electric hoists 

and winches 

Defective coil

 

Motor must be repaired by a specialist 

If the unit is suitable for explosive atmosphere, the motor 
must be returned to the manufactuerer for repair!*

 

Rotor is rubbing

 

Brake does not release

 

See problem “Brake does not release”

 

Defect of capacitor (only for alternating current 1). 

Replace the capacitor 

Defect of starter relay (only for alternating current 1). 

Replace the starter relay 

Phase failure (only direct control) 

Find the cause and repair 

Motor does not brake or has excessive afterrunning.

 

Electric hoists 

and winches 

Switching error after intervention in the electric circuit

 

Check the electric connection of the brake acc. to 

the wiring diagram 
          

 

For motor driven 

units. 

Brake linings are worn or dirty.

 

Brake lining carrier must be changed completely  

If the unit is suitable for explosive atmosphere, the brake 

must be returned to the manufacturer for repair!*

Air gap is too large

 

Re-adjust the air gap 

If the unit is suitable for explosive atmosphere, the brake 
must be returned to the manufacturer for repair!*

Brake does not release

 

Electric hoists 

and winches 

Brake rectifier defective

 

Replace the brake rectifier 

If the unit is suitable for explosive atmosphere, the brake 
must be returned to the manufacturer for repair!*

Brake current relay defective

 

Replace the brake current relay 

Brake coil is defective 

Replace the brake coil 

If the unit is suitable for explosive atmosphere, the brake 
must be returned to the manufacturer for repair!*

 

Permissibe air gap is exceeded due to worn out brake 

lining

 

Re-adjust the air gap and exchange the brake lining 

if necessary 

           

 

If the unit is suitable for explosive atmosphere, the brake 
must be returned to the manufacturer for repair!*

Power drop in the mains power line > 10%

 

Provide correct power supply voltage

 

Pneumatic 

hoists and 

winches 

Operation pressure/ quantity of air is too low 

Check connection to mains supply 

Fuses burnt out or motor contactor is triggered

 

Electric hoists 

and winches 

Short circuit in component

 

Eliminate the short circuit

 

Motor has a short circuit in the body or windings

 

Correct the problem by a specialist 

For EX-hoists, please clarify with the manufacturer what 
to do!*

 

Motor is switched incorrectly

 

Correct the switching

 

Wrong type of fuse

 

Replace the fuse with correct one 

(see table "fuses")

 

*) as far as applicable 
 

Pos: 20.2.2 /1_HADEF/16-ABHILFE/Krane/02.Tabelle - Krane - E+H+P @ 2\mod_1289230970349_52.docx @ 16702 @  @ 1 

 

Problem

 

Cause

 

Remedy

 

Trolley is hardly to travel  

Obstacle on the beam 
Deformation in the construction 

Remove the obstacle 
Examine the crane, have it repaired by an 
authorised workshop if necessary 

 

Pos: 21.1 /1_HADEF/17-AUßERBETRIEBNAHME/*Ü1*/#. Kapitel - Außerbetriebnahme @ 0\mod_1172648336045_52.docx @ 417 @  @ 1 

 

 

 

Содержание EEE

Страница 1: ...Single Girder Electric Overhead Travelling Crane Type EEE Pos 1 4 1_HADEF TITELSEITE Bauarten auch als Adapterkran 2 mod_1288102918176_52 docx 16586 1 also available as adapter crane Pos 1 5 1_HADEF T...

Страница 2: ...ww hadef com Subject to changes Pos 4 1_HADEF ALLGEMEIN Allgemein 4 Inhaltsverzeichnis Inhaltsverzeichnis 1 2 0 mod_1171286846268_52 docx 56 1 Table of Contents 1 Information 3 1 1 Indications to dete...

Страница 3: ...ertified quality assurance system as per ISO 9001 The production of components at our work is subject to strict intermediate checks After assembly each product is subject to a final test with overload...

Страница 4: ...d other useful information Danger from electricity Danger from explosive area Pos 6 2 2 1 1_HADEF 2 SICHERHEIT Allgemein Sorgfaltspflicht des Betreibers 04 Sorgfaltspflicht des Betreibers 0 mod_117205...

Страница 5: ...othes that are too big wide Pos 6 3 1_HADEF 2 SICHERHEIT Bestimmungsgem e Verwendung 01 Alle au er 380 2 mod_1300955165911_52 docx 18464 1 2 4 Appropriate use The permitted safe working load of the de...

Страница 6: ...the immediate vicinity must be informed by calling to them Please pay attention to the regulations for load carrying devices UVV for both positive and non positive methods of attaching loads The lift...

Страница 7: ...Pneuma Cranes acco dard the cran riage version lly Version A le the end ca ageous 2 mod_1288082417896_52 docx 16570 1 Adapter C cranes are s n beam can 2 mod_1290678435939_52 docx 17350 1 carriages ar...

Страница 8: ...luding running wheels and travel drive Standard as welded version C As option available with screw fittings version A B Wheels Machined steel wheels with ball bearing and wheel flange Pos 8 3 3 2 1_HA...

Страница 9: ...00 4747 4765 250 0 55 5891 10000 6000 1600 5126 5228 250 0 55 1704 9000 1600 5500 5488 250 0 55 2361 11000 1600 5714 6016 250 0 55 2915 12000 2200 5841 6143 315 0 75 3311 14000 2200 6077 6379 315 0 75...

Страница 10: ...ng r the hoist M oist accordin motor driven iagram sembly a me rane embly Ad ly arriages ers with scre evices altern ble adapters screws tight dapter plates ersion A oles into the m rding to the t he...

Страница 11: ...87534915_52 docx 440 1 ople that are n They mus that the oper g personnel 1 mod_1264760146475_52 docx 11700 1 wn control sw 1287553567138_52 docx 16427 1 t control 6 rgency stop ction switch g slow fa...

Страница 12: ...duty cycle i e intermittent operation S4 40 ED as per VDE 0530 means that in a period of 10 minutes the motor can operate no matter the height of the load for 4 minutes It is therefore irrelevant whet...

Страница 13: ...ine acc VDE 100 9 2 2 Control connection Control cable with connection plug as standards Plug in for setting in operation Changes at connection cable are only allowed by am expert 9 2 3 Cable connecti...

Страница 14: ...y must be effected with utmost care Only qualified persons may do this work Servicing and maintenance work must only be done when the hoist is not loaded Records must be kept of all test results and m...

Страница 15: ...devices out of operation and effect a General Overhaul Further use of the equipment is only allowed after a licensed qualified person has proofed that further use is possible without doubt and the co...

Страница 16: ...eralyn SF 320 Ca tioned by ord uble ention to the th the equipm unit against arning note in working area d the chapter epair of faults of failures ple 2 1 TION d by wear o c must be r ge ls are life t...

Страница 17: ...ace the starter relay Phase failure only direct control Find the cause and repair Motor does not brake or has excessive afterrunning Electric hoists and winches Switching error after intervention in t...

Страница 18: ...easures are as above Also read the chapter Transport and storage 17 2 Final decommissioning disposal Measures are as above After disassembly ensure that the disposal of the equipment and any materials...

Отзывы: