23
Controller Installation
4.5 Interface Connector Descriptions
Note:
All interface receptacles are covered with push-on caps. These caps are designed to protect
the connector pins from dirt and moisture and should be attached to any receptacle not in use.
The interface connector ports are located on the left side of the flow meter case. The 950
Flow Meter comes standard with three interface ports.
•
12 V dc (Power Input)
•
RS232 (Serial Communications Port)—(See
and programming details).
•
Sampler (Automatic Liquid Sampler Control)
In addition, the flow meter can be connected to a wide variety of optional peripheral
devices:
One or a combination of up to three sensors can be connected to the 950 Flow Meter,
depending on the system configuration.
4.6 12 V dc Connections
This connection supplies power to the flow meter. Power sources include a battery
(Ni-Cad or Lead Acid), an ac power pack, or an external source such as a deep-cycle
marine battery or vehicle cigarette lighter connection. Refer to
for more information.
Although the 950 Flow Meter will operate on any attached 12 V dc power supply, the
instrument will assume it is battery operated if it detects a less than 14.2 V dc input and
will assume it is operating on an ac power converter if it detects a greater than 14.2 V dc
input
.
•
Rain Gauge (
)
•
Modem (
)
•
pH (
•
Analog Inputs (
•
ORP (
•
Alarm Relays (
)
•
Dissolved Oxygen (
)
•
4–20 mA Current Loop(
•
Conductivity (
)
•
Downlook Ultrasonic Depth Sensor (
•
In-Pipe Zero Deadband Ultrasonic Depth Sensor (
•
Submerged Area/Velocity Sensor (
)
•
Low Profile Velocity Only Sensor (
•
Submerged Depth Only Sensor (
•
Bubbler Depth or Bubbler Area/Velocity Sensor (
Table 2 12 V dc Connector Pin Assignments
Pin
Signal Description
A
Ground
B
12 to 17 V dc, unregulated
Содержание Sigma 950
Страница 2: ......
Страница 6: ...4...
Страница 20: ...18 Introduction...
Страница 34: ...32 Basic Programming Setup...
Страница 50: ...48 Sensor Installation...
Страница 82: ...80 Maintenance...
Страница 83: ...81 Appendix A Program Flow Charts Figure 22 Overview of Basic Program Menus...
Страница 84: ...82 Program Flow Charts Figure 23 Setup Flow Chart...
Страница 85: ...83 Program Flow Charts Figure 24 Options Flow Chart...
Страница 86: ...84 Program Flow Charts Figure 25 Alarms Menus Flow Chart...
Страница 87: ...85 Program Flow Charts Figure 26 Calibration Menus Flow Chart Page 1...
Страница 88: ...86 Program Flow Charts...
Страница 102: ...100 Programming Features...
Страница 106: ...104 Primary Devices Head Measurement Locations...
Страница 126: ...124 SCADA Modbus System Guidelines...