Material

316 L SS

316 L SS

Maximum temperature (°C)

150 

150 

Maximum pressure (bars)

25 

25 

Sensor connection

Tri-Clamp 2 inch

Tri-Clamp 1½ inch

Sample connection

¼ inch NPT

¼ inch NPT

General information

In no event will the manufacturer be liable for direct, indirect, special, incidental or consequential
damages resulting from any defect or omission in this manual. The manufacturer reserves the right to
make changes in this manual and the products it describes at any time, without notice or obligation.
Revised editions are found on the manufacturer’s website.

Safety information

N O T I C E

 

The manufacturer is not responsible for any damages due to misapplication or misuse of this product including,
without limitation, direct, incidental and consequential damages, and disclaims such damages to the full extent
permitted under applicable law. The user is solely responsible to identify critical application risks and install
appropriate mechanisms to protect processes during a possible equipment malfunction.

Please read this entire manual before unpacking, setting up or operating this equipment. Pay
attention to all danger and caution statements. Failure to do so could result in serious injury to the
operator or damage to the equipment.
Make sure that the protection provided by this equipment is not impaired. Do not use or install this
equipment in any manner other than that specified in this manual.

Use of hazard information

D A N G E R

 

Indicates a potentially or imminently hazardous situation which, if not avoided, will result in death or serious injury.

W A R N I N G

 

Indicates a potentially or imminently hazardous situation which, if not avoided, could result in death or serious
injury.

C A U T I O N

 

Indicates a potentially hazardous situation that may result in minor or moderate injury.

N O T I C E

 

Indicates a situation which, if not avoided, may cause damage to the instrument. Information that requires special
emphasis.

4

   

English

Содержание POLYMETRON 8310

Страница 1: ...ctivity Probes 12 2016 Edition 4 User Manual Bedienungsanleitung Manuale d uso Manuel d utilisation Manual de usuario N vod k pou it Brugervejledning Gebruikershandleiding Instrukcja obs ugi Bruksanvi...

Страница 2: ...English 3 Deutsch 14 Italiano 25 Fran ais 36 Espa ol 47 e tina 58 Dansk 69 Nederlands 80 Polski 91 Svenska 102 Suomi 112 T rk e 122 2...

Страница 3: ...connection inch NPT inch NPT 8312 8317 8394 Applications Waste water and drinking water Food and pharmaceutical industries sterilized K cm 1 1 0 0 01 Accuracy 2 2 Transmitter measurement range 1 S to...

Страница 4: ...responsible to identify critical application risks and install appropriate mechanisms to protect processes during a possible equipment malfunction Please read this entire manual before unpacking setti...

Страница 5: ...indicates the presence of devices sensitive to electrostatic discharge and indicates that care must be taken to prevent damage to them This symbol when noted on a product indicates the instrument is...

Страница 6: ...12 50 75 DN20 or inch 8315 28 117 DN90 or 4 inch 8316 28 80 DN50 or 2 inch 8317 28 90 DN75 or 3 inch 8394 21 5 65 5 DN50 or 2 inch Figure 3 Flow chamber dimensions Cable connections C A U T I O N Conn...

Страница 7: ...transmitter for a detailed description of the cable connectors on the transmitter Probe installation In Figure 5 on page 8 Figure 6 on page 8 and Figure 7 on page 9 the annotations A B and C indicate...

Страница 8: ...A standards for Cleaning In Place CIP Figure 6 8394 Probe In a bypass POLYMETRON flow chambers are designed not to retain air bubbles Minimum recommended flow rate 100 mL minute 6 L hour with homogene...

Страница 9: ...o indicate a 2 electrode probe Set the cell constant On the PROGRAMMING MEASURE PROBE menu set the cell constant value K of the probe This value is indicated on the probe certificate and is determined...

Страница 10: ...smitter Note It is advisable to calibrate the temperature before the conductivity probe Temperature calibration This is an important step during commission to take into account the cable resistivity a...

Страница 11: ...nector with the values below Temperature C 0 10 20 30 40 50 Resistance 100 00 103 90 107 70 111 67 115 54 119 40 Temperature C 60 70 80 90 100 Resistance 123 24 127 07 130 89 134 70 138 50 Electrodes...

Страница 12: ...conductivity sensor K 0 01 2 inch 51 mm clamp 08394 A 2000 2 electrode conductivity sensor K 0 01 2 inch 51 mm clamp with certificate of conformity 08394 A 2011 Cables Description Item no Female conn...

Страница 13: ...elding ferrule H 13mm 08394 A 0380 Kit for 8394 2 inch clamp with EPDM gasket clamp and 316L SS welding ferrule H 13mm 08394 A 0510 Spare parts Description Item no EPDM gasket for 1 inch clamp fasteni...

Отзывы: