Specifications

Specifications are subject to change without notice.

Specification

Details

Dimensions (W x D x H)

37 x 30 x 170 mm (1.45 x 1.18 x 6.69 in.)

Enclosure rating

IP67 

Weight

135 g (0.297 lb) with batteries

Power requirements (internal)

AAA alkaline batteries (4x)

Battery life

450 hours

Operating temperature

0 to 50 °C (32 to 122 °F)

Storage temperature

–20 to 60 °C (–4 to 140 °F)

Operating humidity

80% (non-condensing)

Altitude

2000 m (6562 ft)

Instrument range

0.00 to 10.00 ppt

Resolution

0.01 ppt

Accuracy

±1% FS

Calibration points

1 point

Note: Temperature calibration is not available.

Auto-recognition calibration standard

12.88 mS/cm

Certifications

CE mark, FCC, Industry Canada, KC Mark, RCM, China RoHS

Warranty

1 year for manufacturing faults only. Damage from use is not covered.

General information

In no event will the manufacturer be liable for direct, indirect, special, incidental or
consequential damages resulting from any defect or omission in this manual. The
manufacturer reserves the right to make changes in this manual and the products it
describes at any time, without notice or obligation. Revised editions are found on the
manufacturer’s website.

Safety information

N O T I C E

 

The manufacturer is not responsible for any damages due to misapplication or misuse of this
product including, without limitation, direct, incidental and consequential damages, and disclaims
such damages to the full extent permitted under applicable law. The user is solely responsible to
identify critical application risks and install appropriate mechanisms to protect processes during a
possible equipment malfunction.

Please read this entire manual before unpacking, setting up or operating this equipment.
Pay attention to all danger and caution statements. Failure to do so could result in serious
injury to the operator or damage to the equipment.
Make sure that the protection provided by this equipment is not impaired. Do not use or
install this equipment in any manner other than that specified in this manual.

Use of hazard information

D A N G E R

 

Indicates a potentially or imminently hazardous situation which, if not avoided, will result in death
or serious injury.

2

Содержание Pocket Pro Salinity

Страница 1: ...User Manual DOC022 52 80400 Pocket Pro Salinity 1 ...

Страница 2: ...serves the right to make changes in this manual and the products it describes at any time without notice or obligation Revised editions are found on the manufacturer s website Safety information NOTIC E The manufacturer is not responsible for any damages due to misapplication or misuse of this product including without limitation direct incidental and consequential damages and disclaims such damag...

Страница 3: ...Class B Supporting test records reside with the manufacturer This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil numérique de classe B répond à toutes les exigences de la réglementation canadienne sur les équipements provoquant des interférences FCC Part 15 Class B Limits Supporting test records reside with the manufacturer ...

Страница 4: ...ro salinity tester measures the salinity of general water samples Refer to Figure 1 This tester is waterproof and floats Figure 1 Product features 1 Sensor cap 3 Keypad 5 Lanyard attachment 2 Sensor 4 Display 6 Pocket clip Product components Make sure that all components have been received Refer to Figure 2 If any items are missing or damaged contact the manufacturer or a sales representative imme...

Страница 5: ...pe and are inserted in the correct orientation Do not mix new and used batteries WA RNING Fire hazard Battery substitution is not permitted Use only alkaline batteries Install the four AAA alkaline batteries in the tester Refer to the illustrated steps in Figure 3 Figure 3 Install the batteries User interface and navigation Display description Figure 4 shows the measurements calibration standard i...

Страница 6: ...the battery power level Flashes when the battery power is less than 10 Shows when the lock feature is on When the lock feature is on the parameter value on the display does not change Push to set the lock feature to on or off Shows when the tester is in calibration mode Keypad description Figure 5 shows the keypad Table 2 gives the key descriptions Figure 5 Keypad overview 1 Power key 2 Calibratio...

Страница 7: ...utes in the sample or tap water Calibrate Items to collect One auto recognition calibration standard 1 Set the power to on 2 Remove the cap from the sensor 3 Push to go to calibration mode The auto recognition standard s the tester expects to measure shows on the bottom line 4 Rinse the sensor and cap with deionized water and blot dry 5 Pour the calibration standard shown into the cap to the fill ...

Страница 8: ...on default or off When set to on power is automatically set to off after 8 minutes of no activity rSEt Change the settings to the factory defaults Yes or No default When set to Yes changes the settings to the factory settings and default values 3 To change the value of the setting push or 4 When done with changes push and hold until End shows to go to continuous measurement mode Maintenance CA U T...

Страница 9: ... sample temperature is within the operating temperature range of the tester Contact technical support as necessary Note The tester can still be used if a temperature sensor failure has occurred but without automatic temperature compensation Battery icon flashes The batteries have less than 10 power remaining Replace all four batteries Refer to Install the batteries on page 5 Replacement parts WA R...

Страница 10: ...hach com www hach com HACH LANGE GMBH Willstätterstraße 11 D 40549 Düsseldorf Germany Tel 49 0 2 11 52 88 320 Fax 49 0 2 11 52 88 210 info hach lange de www hach lange de HACH LANGE Sàrl 6 route de Compois 1222 Vésenaz SWITZERLAND Tel 41 22 594 6400 Fax 41 22 594 6499 Hach Company Hach Lange GmbH 2014 All rights reserved 12 2014 Edition 2 ...

Отзывы: