Specification
A1000
A1000XP
Inputs/Outputs (communications)
Serial
RS232, three connectors (Data Acquisition, Printer
3
and
Diagnostics)
RS485, reserved for the local BNC cable for the
analyzer
Analog
4–20 mA, opto-isolated
12 VDC, non-isolated at 0.5 A (maximum)
Digital
Two digital inputs, maximum input 5–30 VDC and
1–10 mA, opto-isolated
Two digital outputs that supply 5–30 VDC, opto-isolated
Bias
12 VDC, 0.5 A
Network protocol
RS485
Maximum analyzers
8 per C80 controller
Maximum
C80 controllers (any
configuration)
8
Network cabling
Shielded twin-axial, twist-lock BNC
Safety rating
Certified to UL and CSA safety standards by CSA.
Marked with cCSAus and CE.
Thermal printer
Specification
Details
Method
Thermal, serial, dot-matrix
Format
9 dots high x 7 dots wide
Speed
52.5 characters per second (cps)
Width
89.6 mm
Specification
Details
Paper size
112 mm, 40-column
Buffer
7400 characters
Temperature range
0 to 40 °C (32 to 104 °F)
Humidity
30 to 80% relative humidity, non-condensing
Power (via wall transformer)
120 VAC, 60 Hz standard (230 VAC, 50 Hz
optional)
NiCad
4
4.8 VDC, 1.5 A
Maximum power consumption Negligible
Dimensions (W x D x H)
160 x 66.5 x 170 mm (6.3 x 2.6 x 6.7 in.)
Interface
RS232 serial, 1200 baud
General information
In no event will the manufacturer be liable for direct, indirect, special,
incidental or consequential damages resulting from any defect or
omission in this manual. The manufacturer reserves the right to make
changes in this manual and the products it describes at any time, without
notice or obligation. Revised editions are found on the manufacturer’s
website.
Safety information
N O T I C E
The manufacturer is not responsible for any damages due to misapplication or
misuse of this product including, without limitation, direct, incidental and
consequential damages, and disclaims such damages to the full extent permitted
under applicable law. The user is solely responsible to identify critical application
risks and install appropriate mechanisms to protect processes during a possible
equipment malfunction.
Please read this entire manual before unpacking, setting up or operating
this equipment. Pay attention to all danger and caution statements.
4
A1000 S20P model only
English