HAC-MLW Metering Module User Manual V1.0
P
15
7.2.9 Interface-
【
Running Meter Test
】
Real-time display of data in the process of setting parameters, and supports valve control.
1). Valve control: fill in the DeviceEui number, click the button “valve open” or “valve close” , and then use a
magnet to trigger the water meter to report data to achieve valve control.
2). Clear the data: click the button "Clear the Data" to clear the data displayed in the list.
It’s shown as below:
8. Production Test Flow
8.1 Wireless communication mode
8.1.1 The production setting steps can be referred as below:
1). Check "Use remote" and "Base meter with valve".
2). Preset the parameters of meter.
3). Use the scanner to scan the QR code label of meter to obtain DeviceEui, or manually enter it.
4). After clicking "Setting", the meter will be triggered to report data and start production test. After the
production test is completed, the corresponding prompted message will be output on the upper right. It’s
shown as below: