HAC-LBee/S manual V3.X SHENZHEN HAC TECHNOLOGY CO., LTD.
FAX:+86-755-23981007 E-MAIL
:
-
14 -
API mode.
4. Under the API mode, input 3-character command sequence
“
+++
”
will let the module switch to
AT Command mode.
5. Under API mode, when using AT Command to setup transparent mode (ATAP 0), the module will
switch to transparent mode.
5.2 AT Command
AT
Command
Command
Category
Name and Description
Parameter Range
Default
Firmware
Version
WR
Special
Write. Write all configurable parameter
values to non-volatile memory so that
parameter modifications persist through
subsequent power-up or reset.
-
-
>=0x1000
RE
Special
Restore
Defaults.
Restore
module
parameters to factory defaults.
-
-
>=0x1000
FR
Special
Software Reset. Immediately performs a
hard reset.
-
-
>=0x1000
CH
Networking
Channel. Set/Read the channel number used
for transmitting and receiving data between
RF modules (uses 802.15.4 protocol channel
numbers).
0x0B - 0x1A
0x0B
>=0x1000
ID
Networking
PAN ID. Set/Read the setup PAN (Personal
Area Network) ID.
0 - 0xFFFF
0x234
>=0x1000
DH
Networking
64-bit Destination Address High. Set/Read
the upper 32 bits of the 64-bit destination
address. When combined with DL, it defines
the
destination
address
used
for
transmission. 0x000000000000FFFF is the
broadcast address for the PAN.
0 - 0xFFFFFFFF
0x00
>=0x1000
DL
Networking
64-bit Destination Address Low. Set/Read
the lower 32 bits of the 64-bit destination
address. When combined with DH, DL
defines the destination address used for
transmission. 0x000000000000FFFF is the
broadcast address for the PAN.
0 - 0xFFFFFFFF
0xFFFF
>=0x1000
MY
Networking
16-bit Source Address. Read the RF module
16-bit source address.
0-0xFFFF
0x0001
>=0x1000
SH
Networking
Serial Number High. Set/Read high 32 bits
of the RF module's unique IEEE 64-bit
address.
0 - 0xFFFFFFFF
-
>=0x1000
SL
Networking
Serial Number Low. Set/Read low 32 bits of
the RF module's unique IEEE 64-bit
address.
0 - 0xFFFFFFFF
-
>=0x1000
SM
Sleep
Sleep state. Set/read the sleep state of
module
0-5
0
>=0x1000
AP
Serial
Interfacing
API Enable. Disable/Enable API Mode.
0 - 1
0 = Transparent
1 = API enabled
0
>=0x1000
BD
Serial
Interfacing
Interface Data Rate. Set/Read the serial
interface data rate for communications
between the RF module serial port and host.
1-7
1 = 2400
2 = 4800
3 = 9600
4 = 19200
5 = 38400
6 = 57600
7 = 115200
3
>=0x1001
CN
AT Command
Mode Options
Exit Command Mode. Explicitly exit the
module from AT Command Mode.
-
-
>=0x1000
HV
Diagnostics
Hardware Version. Read hardware version
of the RF module.
0 - 0xFFFF
(Read only)
-
>=0x1000