HABCO® TECHNICAL DOCUMENT - C096832 • 10126169
© HABCO Manufacturing Inc. “HABCO®, Cassette®, Cold Space Merchandiser®” are registered trademarks of HABCO Manufacturing Inc. Domestic and International Patents. Page 6
noted previous in this section.
This thermostat displays a numeric setting range. It is preset at mid-
range numeral of “5” to maintain product temperatures to the factory
preset noted previously.
1. Press RED or Blue arrow to adjust numeric setting.
HABCO® recommends a single numeral adjustment at a time, if
needed. After adjustment, it will take at
minimum 2 hours for the
cabinet temperature to stabilize at the new setting. For each ad
-
justment, follow this procedure with waiting period thereafter.
FIG. E2
COOLING FAN(S)
ON MODE
UNIT COOLING
MODE ON SYMBOL
ADJUST
WARMER KEY
ADJUST
COLDER KEY
F. LIGHTING
WARNING: RISK OF DEATH, FIRE, EXPLOSION, ELECTRICAL SHOCK AND/OR
OTHER PERSONAL INJURY!
DO NOT ACCESS MECHANICALLY FASTENED AREAS WITHOUT PERMIS
-
SION OF OWNER AND READING AND UNDERSTANDING PRODUCT
MANUAL.
DISCONNECT POWER BEFORE ACCESSING MECHANICALLY FASTENED
AREAS.
MAINTENANCE AND REPLACEMENT OF LED LIGHT STRIPS AND RELAT-
ED DRIVER COMPONENTS TO BE PERFORMED BY A QUALIFIED
TECHNICIAN ONLY.
•
SE18/24/28 Glass Door model Light Switch is located on the right
front face of the horizontal lighting assembly, as you face the appli
-
ance. Switch controls both sign and interior on SE18M and SE24M.
•
SE42/46 Glass Door model Light Switch is located at the rear top of
the center post above the lighting array.
3. Solid Door Models with Incandescent Interior Lighting:
i.
Incandescent lamps are located on the interior upper front
cabinet face. Replace with maximum 40 Watt, coated appli
-
ance lamp only.
G. CASSETTE® ACCESS & REMOVAL FOR STANDARD MAINTENANCE
WARNING: RISK OF DEATH, FIRE, EXPLOSION, ELECTRICAL SHOCK AND/OR
OTHER PERSONAL INJURY!
DO NOT ACCESS MECHANICALLY FASTENED AREAS WITHOUT PERMIS
-
SION OF OWNER AND READING AND UNDERSTANDING PRODUCT
MANUAL.
DISCONNECT POWER BEFORE ACCESSING MECHANICALLY FASTENED
AREAS.
INSPECT POWER CORD FOR ANY DAMAGE PRIOR TO POWERING AND
WHENEVER HABCO® CASSETTE® IS EXCHANGED OR APPLIANCE IS MOVED.
DO NOT PLUG THIS APPLIANCE INTO WALL RECEPTACLE IF POWER
CORD IS DAMAGED.
DO NOT ACCESS MECHANICALLY FASTENED AREAS WITHOUT PERMIS
-
SION OF OWNER AND READING AND UNDERSTANDING PRODUCT
MANUAL.
DISCONNECT POWER BEFORE ACCESSING MECHANICALLY FASTENED
AREAS.
WARNING: RISK OF PERSONAL INJURY!
EMPLOY BEST HEALTH AND SAFETY LIFTING PRACTICES WHEN REMOV-
ING SHIPPING PLATFORM(S); LEVELING CABINET; REVERSING DOORS; AND
MOVING APPLIANCE. IF IN DOUBT, ASK FOR HELP.
USE CARE WHEN HANDLING OR CLEANING METAL PARTS.
1. To access single door Cassette® loosen two bolts located on the
lower kick plate of the air flow grill (Fig G1).
FIG. G1
2. Then remove two screws located in flange at the top of air flow
grill. Grill will lift up and off the bottom screws (Fig G1).
FIG. G2