background image

37

ROSSI 

GEARMOTORS

UT.D 123 rev. 3

16.5 Overall dimensions

17 - “ON-OFF” oil level switch

 II 1/2 G EEx d IIC T6 

17.1 Specifications

It is a level control device with reed contacts in a supporting stem  

moved by the magnetic field activated by the magnets included in 

the float.

The float and the supporting stem are included in a hollow column of 

not magnetic material connected to the gear reducer casing through 

communicating vessels.

Connecting features:

- 2 wires (see Fig. 1)

- Max voltage: 350 V

- Max current: 1,5 A

- 1 cable input 1/2” UNI6125 – IP65

- G 1” brass joint.

17.2 Calibration

The switch is supplied ready for use; when level goes down approx 

5 mm, the switch goes on and contact opens. When filling oil in the 

gear reducer it is necessary 

to verify that device is properly cali-

brated.

 If any problems occur during this operation contact ROSSI 

MOTORIDUTTORI.

17.3 Installation and maintenance

The accessories used for cable input and for covering unused holes 

must be certified according to EN 50014 and EN 50018 standards.

The level switch must be installed and maintained according to plant 

and maintenance standards for environments classified to explosion 

proof  for  the  presence  of  gas  (i.e.:  EN  60079-14,  EN  60079-17  or 

other national standards). The level switch box must be earth con-

nected. Only proper tools have to be used for installing and disas-

sembling  the  level  switches.  Never  use  electrical  connections  for 

manual installation.

The level switch cables must be installed in  mechanical protections 

such as conduit pipes with separating joints at the top and the end 

of the pipes.

It is recommended to use cables of 0,22 mm

2

 section. 

All  active/passive  safety  barriers  and  connected  devices  (insulated 

amplifiers,  relays)  if  any  must  be  certified  according  to  EN  50020 

standards  with  [EEX  ia]  IIC  protection  and  have  to  be  installed  in 

a safe area. The contacts are “REED” type and can carry up to ca. 

100 000 000 operations during their life cycle. The switch power is 

relatively low (30-100 VA/W depending on application). For the safe 

use of the contacts it is recommended to drive inductive/capacitive   

power-loads  through  auxiliary  relays  or  to  use  transient  dampers/

suppressors.

spanner

spanner

Fig. 1 Terminal box connections

16 - (Oil or bearing) temperature probe

16.1 Specifications of «EEx d» explosion-proof probe

II 2 GD EEx d IIC TX IP65

It is a thermistor Pt 100 featuring:

- platinum wire with 100 

Ω

 at 0° C 

- precision class B

- max current 40 mA

- max power at temperature probe 0,5 W

- max power at connection head, supply signal 1 W

- connection with 3 wires according to IEC 751 (see Fig. 1)

- gaiter AISI 316 diameter 6 mm

- alluminium case supplied without cable gland

- coupling with sliding probe and 1/2” NPT-M thread

16.2 Specifications of «EEx ia» fail-safe probe 

II 2 GD EEx ia IIC TX IP6x

It is a thermistor Pt 100 featuring:

- platinum wire with 100 

Ω

 at 0° C 

- 3 wire connection according to IEC 751 (see fig.1)

- gaiter AISI 316 diameter 6 mm

- alluminium case supplied without cable gland

- coupling with sliding probe and 1/2” NPT-M thread
For the electric specifications and connection wires refer to the specific 

instructions relevant to the probe and to the internal transmitter, if any, 

at 4 ... 20 mA.

16.3 Installation and maintenance

Fit the coupling with sliding probe into the appropriate threaded hole of 

the gear reducer (for the position refer to the attached drawing SPT ...) 

by using a spanner key 24, loosen the hexagon using a 19 mm spanner 

and slide the probe of the thermometer in (up to the point of contact 

when the head of the probe to be checked is closer to gear reducer. 
The electrical connections must be made with copper shielded “twisted” 

wires separated from power cables. Earth connections must be made 

according  to  current  regulations,  connecting  the  internal  and  external 

earth connections.
The body of the probe must be protected against all risks of damage.
Connect the probe to a 

temperature control device

 with 2 operating 

threshold or similar device.
Periodically verify that:
– there is no erosion/corrosion of the gaiter
–  the whole equipment is working efficiently by inserting into the circuit 

a resistance of a known value and simulating a known temperature.

Attention! Assemble and disassemble the probe with gear reducer 

without oil

.

16.4 Calibration

Two operating thresholds are foreseen:

Alert

:  anomalous  increase  of  temperature,  consult  table 

19  and  identify  the  possible  overheating  causes.  If  no 

intervention is possible, please start with the machine stop 

procedure.

Stop

: achieving the maximum temperature allowed, start immediately 

with  the  machine  stop  procedure,  exclude  the  gearmotor  from  the 

power supply. Consult table 19 and check according to table 15.
If not differently stated in the additional documentation attached to pre-

sent manual, please procede as follows:

- Calibration of oil temperature probe

At commissioning end (see ch. 7) when gear reducer or gearmotor achi-

ves steady thermal conditions, measure oil temperature T

oil

 and ambient 

temperature T

amb

 and calibrate the 

operating temperature  

(alert) of the 

device connected with the oil probe at the lowest temperature between 

the following two:

Calculated temperature [°C] = T

oil

 [°C]  – T

amb

 [°C] + 45 [°C]

T

alert

 = 85 [°C]

The temperature of 

machine stop 

may not exceed 

T

stop

 = 100 [°C]

.

- Calibration of bearing temperature probe

Calibrate  the  operating  temperatures  (alarm  and  stop)  of  the  device 

connected to the bearing probe as follows:

T

alert

 = 100 [°C]

T

stop

 = 110 [°C]

Fig. 1 Diagram

Fig. 2 Diagram

Red

Red

White

Red

Red

White

Содержание G05

Страница 1: ...up plementari eventualmente necessarie devono essere adottate e garantite da chi è responsabile dell installazione IMPORTANTE i componenti forniti da ROSSI MOTORIDUTTORI sono destinati ad essere incorporati in apparecchi o sistemi finiti e ne è vietata la messa in servizio fino a quando l apparecchio o il sistema nel quale il componente è stato incorporato non sia stato dichiarato conforme alla Di...

Страница 2: ...pedizioniere Non mettere in servizio riduttori o motoriduttori dan neggiati anche solo lievemente o se non ritenuti idonei all utilizzo previsto in tal caso interpellare ROSSI MOTORI DUTTORI 3 2 Targa di identificazione Ogni riduttore è dotato di targa di identificazione di alluminio ano dizzato contenente le principali informazioni tecniche relative alle caratteristiche funzionali e costruttive e...

Страница 3: ...la posizione indicata dallo schema SPT allegato a UT D 123 e seguendo le indicazioni dei paragrafi 16 17 e 18 Collegare ad adeguata apparecchiatura di monitoraggio e intervento tali sensori ved schema SPT e cap 16 17 e 18 In presenza di apparecchiature atte alla variazione di velocità adottare un sistema di controllo della stessa es encoder collegato a un sistema di sicurezza per non su perare mai...

Страница 4: ...amente per velocità perife riche superiori occorre effettuare l equilibratura dinamica Quando il collegamento tra riduttore e macchina o motore è realiz zato con una trasmissione che genera carichi sull estremità d albero ved fig 3 è necessario che non vengano superati i carichi di progetto dell applicazione lo sbalzo della trasmissione sia ridotto al minimo le trasmissioni a ingranaggi non abbian...

Страница 5: ...a regola zione utilizzare la manopola posizionata sulla testa della valvola Per temperatura ambiente minore di 0 C interpellarci Si consigliano per la temperatura di intervento valori di taratura 50 65 C Tabella 1c Natura del carico e durata di funzionamento E04 Natura del carico della macchina azionata Durata di funzionamento h Rif Descrizione 3 150 6 300 12 500 25 000 50 000 2 h d 2 4 h d 4 8 h ...

Страница 6: ...uenza di avviamento doppia di quella effettiva per motore a scoppio moltiplicare fs per 1 25 pluricilindro 1 5 monocilindro durata massima dei sovraccarichi 15 s degli avviamenti 3 s se superiore e o con notevole effetto d urto interpellarci un numero intero di cicli di sovraccarico o di avviamento completati non esattamente in 1 2 3 o 4 giri dell albero lento se esattamente considerare che il sov...

Страница 7: ...77 2 49 224 4 91 4 46 3 81 3 49 3 24 2 48 2 23 180 4 42 3 98 3 4 3 11 2 21 2 01 140 3 9 3 51 3 01 2 75 1 97 112 3 48 3 14 2 68 1 75 901 3 14 2 85 1 400 23 4 21 8 18 9 17 4 16 1 12 5 11 4 10 3 9 3 1 120 20 2 18 9 16 3 14 9 13 8 10 8 9 7 8 7 7 8 900 17 4 16 1 13 9 12 7 11 8 9 1 8 3 7 5 6 7 710 15 13 8 11 8 10 8 10 7 7 7 6 3 5 7 560 12 8 11 8 10 1 9 2 8 5 6 6 6 5 44 4 82 450 11 1 10 2 8 7 8 7 4 5 7 5...

Страница 8: ...1 Generalità Effettuare un controllo generale assicurandosi in particola re che il riduttore sia completo di olio sintetico nella corretta quantità con la viscosità adeguata e di una delle marche previste nella tab 6 2 In presenza di un sistema esterno di circolazione dell olio lubrifica zione forzata unità di raffreddamento occorre che l olio sia a livello anche con il sistema esterno pieno di ol...

Страница 9: ...arsi che tutto l olio sia stato espulso o inclinando il riduttore o asportan do l eventuale rimanenza con pompa aspirante Per il successivo riempimento impiegare un filtro per olio con potere filtrante di 25 m Qualora venga smontato il coperchio per i riduttori che ne sono provvisti ripristinare la tenuta con mastice dopo aver pulito e sgrassato accuratamente le superfici di accoppiamento Le viti ...

Страница 10: ...radazione di viscosità ISO indicata in ta bella Il 3 GD c k Il 2 GD c k Il 2 G c k SENZA OLIO salvo diversa indicazione sulla targa di lubrificazione Tappo di carico con filtro e valvola scarico e livello Prima della messa in servizio immettere fino a livello olio sintetico a base di polialfaolefine AGIP Blasia SX CASTROL Tribol 1510 ELF Reductelf SYNTHESE ESSO Spartan SEP KLÜ BER Klübersynth EG4 ...

Страница 11: ...95 6 300 Orientativamente l intervallo di lubrificazione in assenza di inquinamento dall esterno è quello indicato in tabella Per sovraccarichi forti dimezzare i valori Indipendentemente dalle ore di funzionamento sostituire o rigenerare l olio sintetico almeno ogni 5 anni La quantità d olio è individuata dal livello segnalato dall apposito tappo o da altro sistema equivalente tappo di livello a s...

Страница 12: ...J6 k6 per D 38 mm la lunghezza della linguetta deve essere almeno 0 9 la larghezza del pignone assicurarsi che i motori abbiano cuscinetti e sbalzi quota S co me indicato nella tabella sottostante 1 Valori consigliati per contenere al minimo i livelli sonori Sono relativi alla potenza mas sima della grandezza motore e aumentano proporzionalmente con la diminuzione della potenza applicata Possono r...

Страница 13: ...ndo idrosolubile monocomponente a base alchidica preverniciato Polveri epossidiche preverniciato Spessore totale 40 m Fondo epossidico bicomponente preverniciato Smalto idrosolubile Spessore totale 80 m Resistente agli agenti atmo sferici e aggressivi Sovraverniciabile solo dopo sgrassatura e carteggiatura Buona resistenza agli agenti atmosferici e aggressivi Non resiste ai solventi Sovraverniciab...

Страница 14: ...co con filtro e valvola è presente solo grand 100 5 1 6 1 Il tappo di carico è accessibile per la manutenzione 5 1 È stato montato il coperchio di protezione dell unità di bloccaggio 5 1 Gli accessori sonde termiche ecc sono conformi ad ATEX per la zona di impiego 5 1 Si è sicuri che la velocità in entrata non può superare 1 500 min 1 5 1 Sono stati collegati tutti i sistemi di monitoraggio e o si...

Страница 15: ...la Temperatura superficiale fino a regime termico e verificare che Δ T 45 K conservare i valori rilevati per confrontarli con quelli dei rilievi successivi Tenere sotto controllo per le prime 4 h Se il controllo è stato eseguito con strumentazione conservare i valori rilevati per confrontarli con quelli dei rilievi successivi Tenere sotto controllo per le prime 4 h Se il controllo viene eseguito c...

Страница 16: ...gni cambio dell olio o in caso di vibrazioni anomale 8 1 O Assorbimento motore semestralmente per categoria 3 GD trimestralmente mensilmente per categoria 2 GD P Collegamento equipotenziale semestralmente per categoria 3 GD trimestralmente mensilmente per categoria 2 GD Q Pulizia tappo di carico con filtro quando occorre comunque almeno semestralmente 8 5 e valvola R Tenute con labirinto e ingrass...

Страница 17: ...ura collegata alla sonda olio alla più bassa tra le due temperature seguenti Temperatura di calcolo C Tolio C Tamb C 45 C Talert 85 C La temperatura di blocco macchina non può superare Tstop 100 C Taratura sensore temperatura cuscinetto Tarare le temperature di intervento allarme e blocco dell apparec chiatura collegata alla sonda cuscinetto come segue Talert 100 C Tstop 110 C Fig 1 Schema collega...

Страница 18: ... che la custodia del termostato possa ricevere urti da corpi estranei proteggerla adeguatamente La connessione del termostato deve essere fatta da cavi entranti o connettori di tipo antideflagrante cer tificati EExd IIC per B121 120 o EExd IIB per TRI120 Il termostato non deve essere alterato o modificato se la modifica è necessaria interpellare ROSSI MOTORIDUTTORI Quando il termostato è dotato di...

Страница 19: ...ostati flussostati ecc Uno o più denti con ammaccature o sbeccature rugosità eccessiva sui fianchi Interpellare ROSSI MOTORIDUTTORI Cuscinetti in avaria o mal lubrificati o difettosi Interpellare ROSSI MOTORIDUTTORI Cuscinetti a rulli conici con gioco eccessivo Interpellare ROSSI MOTORIDUTTORI Vibrazioni Controllare il fissaggio e i cuscinetti Anello di tenuta con labbro di tenuta usurato bacheliz...

Страница 20: ...grand 180 360 fig 4f Montaggio fig 4a e smontaggio fig 4b fig 4a fig 4b Fissaggio assiale fig 4c Vite grand 32 50 Assi paralleli e ortogonali grand 50 Assi paralleli e ortogonali grand 63 Vite grand 63 161 Assi paralleli e ortogonali grand 64 160 Vite grand 200 250 Assi paralleli e ortogonali grand 180 360 fig 4d Assi paralleli grand MR 3I 50 Assi paralleli grand MR 3I 63 Calettamento con unità di...

Страница 21: ...on measures if necessary must be adopted and assured by the personnel responsible for the installation IMPORTANT the components supplied by ROSSI MOTORIDUTTO RI must be incorporated into machinery and should not be com missioned before the machinery in which the components have been incorporated conforms to Machinery directive 98 37 EC in particular possible safety guards for shaft ends not being ...

Страница 22: ...g main technical information relevant to operating and constructive specifications and defining according to contractual agreements the application limits see fig 1 the name plate must not be removed and must be kept integral and readable All name plate data must be speci fied on eventual spare part orders Attention For the mass stated on name plate remind that it does not consider the lubricant m...

Страница 23: ...e maximum input speed of 1 500 min 1 The gear reducer or gearmotor can be installed only if in the environ ment there is no potentially explosive atmos phere during the instal lation When a motor is assembled to a gear reducer or gearmotor without motor verify that it satisfies the minimum safety requirements according to ATEX 94 9 CE as follows 1 The equipments suitable for zone 1 are also suitab...

Страница 24: ...g freedom of axial movement and sufficient clearance in its couplings to permit minor oscillations always in evidence without provoking dangerous overloading on the gear reducer Lubricate with proper products the hinges and the parts subject to sliding when mounting the screws it is recommended to apply locking adhesives For the mounting of the kit using reaction disc springs sizes 125 parallel sh...

Страница 25: ...t rinse to clear out any possible obstructions A polished metallic pipe with external diameter d stated on table is sufficient for the connection Table 1c Nature of load and running time E04 Nature of load of driven machine Running time h Ref Description 3 150 6 300 12 500 25 000 50 000 2 h d 2 4 h d 4 8 h d 8 16h d 16 24h d a Uniform 0 80 0 90 1 00 1 18 1 32 b Moderate overloads 1 6 x nominal loa...

Страница 26: ...12 1 18 1 25 1 32 Right angle shafts Parallel shafts with 2 fans 1 25 1 4 1 6 1 82 Water cooling by coil 2 Train of gears Gear reducer size P tN kW 400 401 450 451 500 501 560 561 630 631 Parallel shafts 2I 236 265 375 425 530 3I 180 200 280 315 400 4I 132 150 212 236 300 Right angle shafts CI 224 315 C2I 180 200 280 315 400 C3I 132 150 212 236 300 Train of gears Gear reducer size P tN kW 80 81 10...

Страница 27: ... 2 77 2 49 224 4 91 4 46 3 81 3 49 3 24 2 48 2 23 180 4 42 3 98 3 4 3 11 2 21 2 01 140 3 9 3 51 3 01 2 75 1 97 112 3 48 3 14 2 68 1 75 901 3 14 2 85 1 400 23 4 21 8 18 9 17 4 16 1 12 5 11 4 10 3 9 3 1 120 20 2 18 9 16 3 14 9 13 8 10 8 9 7 8 7 7 8 900 17 4 16 1 13 9 12 7 11 8 9 1 8 3 7 5 6 7 710 15 13 8 11 8 10 8 10 7 7 7 6 3 5 7 560 12 8 11 8 10 1 9 2 8 5 6 6 6 5 44 4 82 450 11 1 10 2 8 7 8 7 4 5 ...

Страница 28: ... the lubrication of gear reducer refer to ch 6 2 lubrication table 7 Commissioning 7 1 General Carry out a general check making particularly sure that the gear reducer is filled with synthetic oil in the correct quantity with the proper viscosity and one of the brands recommended in table 6 2 If an external lubricating system is present forced lubrication cooling unit oil is to be filled to the co...

Страница 29: ...quantity if any through a suction pump For the next filling use a 25 m oil filter When dismounting the cap whenever gear reducers are provided with reset the sealing with adhesive on cleaned and degreased mating surfaces All bolts which may be damaged during assembling and disassem bling operations are to be replaced with new ones having equivalent specifications and resistance class Occasional ma...

Страница 30: ...the table Il 3 GD c k Il 2 GD c k Il 2 G c k WITHOUT OIL except different statement on lubrication name plate Filler plug with filter and valve drain and level plug Before commissioning fill to specified level with polyalpha olefines synthetic oil AGIP Blasia SX CASTROL Tribol 1510 ELF Reductelf SYNTHESE ESSO Spartan SEP KLÜBER Klüber synth EG4 MOBIL SHC Molykote L11 having the ISO visco sity grad...

Страница 31: ... 80 95 6 300 An overall guide to oil change interval is given in the table and assumes pol lution free environment Where heavy overloads are present halve the values Apart from running hours replace or regenerate synthetic oil at least each 5 years The oil quantity is given by the level stated by the proper plug or an equi valent system plug for flowing over level plug with dipstick An overall gui...

Страница 32: ... J6 k6 for D 38 mm key length should be at least 0 9 pinion width make sure that the motors have bearing location and overhang distance S as shown in the following table 1 Values advised in order to minimize sound levels These values refer to the maximum power of motor size proportionally they increase when the applied power decreases They can double accepting higher sound levels 3 5 dB A These va...

Страница 33: ...ble single compound alkyd basis primer prepainted Epoxy powder prepainted Total thickness 40 m Dual compound epoxy primer prepainted Water soluble paint Total thickness 80 m Resistant to atmospheric and aggressive agents Suitable for further painting only after degreasing and sanding Good resistance to atmo spheric and aggressive agents Not resistant to solvents Suitable for further coats of singl...

Страница 34: ...ible 5 1 Is the filler plug with filter and valve present only for size 100 5 1 6 1 Is the filler plug accessible for maintenance 5 1 Has the locking assembly cover been mounted 5 1 Are the accessories thermal probes etc compliant with the ATEX specifications for the installation 5 1 Are you sure that the input shaft speed cannot exceed 1500 min 1 5 1 Have you hooked up all required monitoring saf...

Страница 35: ...y condition and verify that ΔT 45 K keep the measu red values to compare them in following measurements Keep under control for the first 4 h When checking by an instrument keep the measured values to com pare them in following measurements Keep under control for the first 4 h When checking by an instrument keep the measured values to com pare them in following measurements Check on starting and af...

Страница 36: ...pecific cooling unit each month for category 2 GD docum I Resistance thermometers every six months J Oil level control switch every six months K Oil thermostats every six months L Cleanliness of external surfaces when necessary also every day dust thickness 0 2 mm M Cooling air passage when necessary also every day N Fitting bolts tightening at any oil change and when excessive vibration is detect...

Страница 37: ... supplied without cable gland coupling with sliding probe and 1 2 NPT M thread 16 2 Specifications of EEx ia fail safe probe II 2 GD EEx ia IICTX IP6x It is a thermistor Pt 100 featuring platinum wire with 100 Ω at 0 C 3 wire connection according to IEC 751 see fig 1 gaiter AISI 316 diameter 6 mm alluminium case supplied without cable gland coupling with sliding probe and 1 2 NPT M thread For the ...

Страница 38: ...culation temperature C Toil C Tamb C 45 C Talert 85 C The machine stop temperature mast not exceed Tstop 100 C 18 4 Installation and maintenance Assemble thermostat in the proper hole of gear reducer see position indicated in the enclosed SPT sketch Carry out electrical connections according to the current standards Protect the body of the thermostat if there may be a risk of being damaged by fore...

Страница 39: ...y of auxiliary bearing lubrication system Check the pump and the pipes Inefficient or out of service oil cooling system obstruc ted filter insufficient oil exchanger or water coil flow rate pump out of service water temperature 20 C Check pump pipes oil filter and safety devices effi ciency pressure switchs thermostats fluxmeters etc One or more teeth with dents or spallings excessive flanks rough...

Страница 40: ... fig 4f Installing fig 4a and removing fig 4b fig 4a fig 4b Axial fastening fig 4c Worm sizes 32 50 Parallel and right angle shaft size 50 Parallel and right angle shaft size 63 Worm sizes 63 161 Parallel and right angle shaft sizes 64 160 Worm sizes 200 250 Parallel and right angle shaft sizes 180 360 fig 4d Parallel shaft size MR 3I 50 Parallel shaft size MR 3I 63 Fitting with shrink disk fig 4g...

Страница 41: ... livello che si trova nella posizio ne indicata nelle figure se guenti Per forma costruttiva B7 il livello è indicato sull asta graduata monta ta sul tappo di carico tappo di carico olio tappo di livello olio tappo di scarico olio fig 1 Forme costruttive e posizione tappi MR 2IV 100 126 Mounting positions and position of plugs MR 2IV 100 126 B3 B6 B7 B8 V5 V6 Cuscinetto ingrassato Entrambi i cusci...

Страница 42: ...earings greased grand 200 nvite 710 min 1 pompa lubrificazione cuscinetti B3 B6 B7 B8 V5 V6 grand 200 n1 710 min 1 pompa lubrificazione cuscinetti size 200 n1 710 min 1 bearing lubrication pump size 200 nworm 710 min 1 bearing lubrication pump 20 Forme costruttive quantità d olio posizione tappi 20 Mounting positions oil quantity and position of plugs Forme costruttive e posizione tappi MR V 100 2...

Страница 43: ...s verify that the dimension X mm between the plug shoulder and oil level corresponds to the value stated in table 3 Before checking ensure that there are no more gas pockets in the oil which is included in the gear reducer Measure as specified in fig 3 Tipo Type R MR 2I R MR 3I f c m p B3 B6 B7 B8 V6 V5 B3 B6 B7 B8 V6 V5 Grand Size q tà q ty x q tà q ty x q tà q ty x q tà q ty x q tà q ty x q tà q...

Страница 44: ...on of plugs MR 2I 3I 100 180 Per f c B3 cuscinetti dell asse lento n 1 lato interno ingrassato 1 o 2 cuscinetti superiori ingrassati Elevato sbattimento d olio la potenza termica nominale PtN cap 5 7 deve essere molti plicata per 0 85 Mounting pos B3 low speed shaft bearings 1 at inner side greased 1 or 2 upper bearings greased High oil splash nominal thermal power PtN ch 5 7 is to be multiplied b...

Страница 45: ... 0 6 0 45 0 45 x 48 48 48 30 50 50 63 64 0 8 0 8 0 8 1 0 95 0 95 x 72 72 72 40 48 48 80 81 1 3 1 3 1 3 2 1 8 1 8 x 90 90 90 50 56 56 C3I B3 B6 B7 B8 V5 V6 50 0 5 0 9 0 5 0 7 0 55 0 55 50 15 50 30 54 54 63 64 1 2 1 8 1 2 1 4 1 35 1 35 x 58 15 58 42 45 45 80 81 1 9 3 0 1 9 2 5 2 3 2 3 x 90 25 90 48 56 56 Tolleranza su quota X 10 mm per grand 63 81 5 mm per grand 50 per cuscinetto esterno pignoni con...

Страница 46: ...ere are no ducts grease the bearing Upper bearings greased Forme costruttive e posizione tappi R 2I 140 360 Mounting positions and position of plugs R 2I 140 360 B3 B6 B7 B8 V5 V6 Eventuale dispositivo lubrificazione asse veloce V5 o pompa lubrificazione cuscinetti V6 se non presente o mancano i condotti i cuscinetti superiori sono ingrassati eventuale elevato sbattimento d olio la potenza termica...

Страница 47: ...en it is not present or there are no ducts grease bearings Upper bearings greased possible high oil splash nominal thermal power PtN ch 5 7 is to be multiplied by 0 85 B6 or V6 0 71 B7 or V5 Forme costruttive e posizione tappi R CI 100 Mounting positions and position of plugs R CI 100 B3 B6 B7 B8 V5 V6 I 2 cuscinetti superiori sono ingrassati The 2 upper bearings are greased Mounting positions and...

Страница 48: ... position of plugs RC 2I 140 360 Eventuale pompa lubrificazione cuscinetti dove non presente o dove non ci sono i condotti i cuscinetti superiori sono ingrassati 1 Foro intermedio eventuale elevato sbattimento d olio la potenza termica nominale PtN cap 5 7 deve essere moltiplicata per 0 85 B6 o in basso 0 71 B7 o in alto Possible bearing lubrication pump when it is not present or there are no duct...

Страница 49: ...lied by 0 85 B6 and V6 0 71 B7 and V5 Forme costruttive e posizione tappi MR 3I 140 360 Mounting positions and position of plugs MR 3I 140 360 B3 B6 B7 B8 V5 V6 Eventuale pompa lubrificazione cuscinetti dove non presente o ove non ci sono i con dotti i cuscinetti superiori sono ingrassati I 3 4 UP2D cuscinetti superiori sono ingrassati Per esecuzione UP2D forma costruttiva B6 n1 335 min 1 il cusci...

Страница 50: ... posizione tappi MR ICI 100 200 Mounting positions and position of plugs MR ICI 100 200 B3 B6 B7 B8 V5 V6 I 2 cuscinetti superiori sono ingrassati The 2 upper bearings are greased 20 Forme costruttive quantità d olio posizione tappi 20 Mounting positions oil quantity and position of plugs Forme costruttive e posizione tappi MR C3I 100 e 125 Mounting positions and position of plugs MR C3I 100 and 1...

Страница 51: ...lied by 0 85 esecuzioni UO2A UO2A sin UO2H UO2H sin designs UO2A UO2A sin UO2H UO2H sin designs UO2V UO2V sin UO2R UO2R sin UO2D UO2D sin UO2H UO2H sin esecuzioni UO2V UO2V sin UO2R UO2R sin UO2D UO2D sin UO2D UO2D sin UO2R UO2R sin B3 B6 B7 B8 V5 V6 Forme costruttive e posizione tappi MR C2I 140 360 Mounting positions and position of plugs MR C2I 140 360 Eventuale pompa lubrificazione cuscinetti ...

Страница 52: ...thermal power PtN ch 5 7 is to be multiplied by 0 85 B6 or V5 and V6 with bevel wheel above 0 71 B7 or V5 and V6 with bevel wheel below eventuale elevato sbattimento d olio la potenza termica nominale PtN cap 5 7 deve essere moltiplicata per 0 9 B6 o V5 e V6 con ruota conica in alto 0 8 B7 o V5 e V6 con ruota conica in basso possible high oil splash nominal thermal power PtN ch 5 7 is to be multip...

Страница 53: ...ione tappi 20 Mounting positions oil quantity and position of plugs R 2I 400 631 R 2I 400 631 1 1 B6 B7 B3 V5 V6 eventuale elevato sbattimento d olio la potenza termica nominale PtN deve essere moltiplicata per 0 9 B6 o V6 0 8 B7 o V5 possible high oil splash nominal thermal power PtN is to be multiplied by 0 9 B6 or V6 0 8 B7 or V5 eventuale elevato sbattimento d olio la potenza termica nominale ...

Страница 54: ...plosive atmosphere as specified by II 3 GD c k Norme applicabili according to the following standards EN 1127 1 EN 13463 1 EN 13463 5 EN 13463 8 EN 60529 Il riduttore o motoriduttore non deve essere messo in servizio fino a quando la macchina o il sistema nel quale è stato incorporato non sia stato dichiarato conforme alle disposizioni delle direttive vigenti Direttiva macchine 98 37 CE allegato I...

Страница 55: ... CE c o TÜV NORD Italia S r l 0044 TÜV NORD CERT GmbH via Persicetana Vecchia 28 40132 Bologna BO Italy con numero deposito fascicolo tecnico 8000314160 ROSSI MOTORIDUTTORI have registered the technical documentation according to the Annex VIII of the Directive ATEX 94 9 EC with TÜV NORD Italia S r l 0044 TÜV NORD CERT GmbH via Persicetana Vecchia 28 40132 Bologna BO Italy with identification numb...

Страница 56: ... CE c o TÜV NORD Italia S r l 0044 TÜV NORD CERT GmbH via Persicetana Vecchia 28 40132 Bologna BO Italy con numero deposito fascicolo tecnico 8000314160 ROSSI MOTORIDUTTORI have registered the technical documentation according to the Annex VIII of the Directive ATEX 94 9 EC with TÜV NORD Italia S r l 0044 TÜV NORD CERT GmbH via Persicetana Vecchia 28 40132 Bologna BO Italy with identification numb...

Страница 57: ...nstallation updating of fs and Pt verification 23 Updating of Par 5 5 Water cooling by coil 25 New paragraph 5 6 Service factor fs requested 25 New paragraph 5 7 Thermal power Pt 28 Updating of paragraph 6 3 Lubrication of extruder support 33 New 11a Table of tightening torques for fastening bolts 34 New 12 Table of tightening torques for the plugs 35 New 14 Table of commissioning checks and opera...

Страница 58: ...58 ROSSI GEARMOTORS UT D 123 rev 3 Pagina lasciata intenzionalmente bianca This page is intentionally left blank ...

Страница 59: ...59 ROSSI GEARMOTORS UT D 123 rev 3 Pagina lasciata intenzionalmente bianca This page is intentionally left blank ...

Страница 60: ...vision of Habasit Canada Limited CA Oakville Ontario Phone 1 905 8274 131 fax 1 905 8252 612 e mail info canada habasit com www rossi group com MEXICO ROSSI GEARMOTORS A Division of Habasit America US Suwanee Phone 1 800 931 2044 fax 1 678 288 3658 e mail rossi info us habasit com www habasitamerica com SWITZERLAND HABASIT AG CH Reinach Basel Phone 41 61 715 15 75 fax 41 61 715 15 56 e mail info c...

Отзывы: