Unbalance Output Inspection
Electrical Diagram
Corrective Action:
Disconnect the motor cables
at the vector drive. Push
[POWER ON]
. Push
[RESET]
to clear any alarms. Use a multimeter to
measure the DC voltage across the following
terminals on the vector drive (see the illustration):
3 and 9
3 and 10
3 and 11
The voltage must be 160-175VDC in all three
readings. If any of the voltage readings is 0V or
330V, then this is a sign of an unbalanced output
from the vector drive.
Vector Drive - Troubleshooting Guide - CHC
Page 9 of 9 pages