Haas Linear Scale Скачать руководство пользователя страница 4

5

Reattach the cover plate over the scale tension set screw, and replace the plastic plug over the tension adjusting

screw.

4

Go to the DEBUG page. Turn servos off by

pressing

[EMERGENCY STOP]

.

Look at the Z-channel travel display (left side of

screen in the middle). The X:xxxx will be used to

adjust tension of scale tape. This number is in

units of µm.

Remove the cover plate and plastic plug. Under

the cover plate is the tape tension locking screw.

This must be loosened. There is a tension

adjusting screw in the end of the scale, use a hex

key on the screw to reduce tension on the scale.

As tension is reduced, the X-axis value on the Z-

channel Travel Display page will change as well.

Continue reducing the tension until the value

stops changing. At this point the tape is fully

relaxed.

Add the value of V, calculated in step 3, to the X-

axis value found on the Z-channel Travel display

page. For example, if X-axis = 8756 then add 567

µm from the example (your number will be

different) and obtain Xaxis= 9323.

Turn the tensioning screw at the end of scale

extrusion and begin tensioning the scale tape

while monitoring the value of X-axis on the Z-

channel Travel Display page. Continue to tension

the tape until the value of Xaxis matches the

calculated value. Sample tests indicate that about

17 revolutions are needed.

Once the correct value of X-axis is achieved,

tighten the tension locking screw. Check to

insure the X-axis value did not change. If it did

change, loosen the lock screw and readjust

tension until correct value is reached.

Linear Scale - Heidenhain - Set Tension

Page 4 of 4 pages