Install Safety Sensors
Connect Air Supply
1
Install the safety sensors on each corner of the
moving enclosure.
• [1] Rear left safety sensor is 33.5" long.
• [2] Front left sensor is 50" long.
• [3] Front right sensor is 18" long with 29
ft cable.
• [4] Rear right sensor is 18" long with the
17 ft cable.
2
Route the safety sensor cables.
• The 33-0606 [1] cable is routed through
the left side column from the factory.
Connect the 33-0606 to the rear left
safety sensor.
• Route the 33-0626 [2] cable from the
rear left to the front left safety sensor.
• Route the 33-0624 [3] cable from the
front left to the front right safety
sensors.
• Route the 33-0623 [4] cable from the
front right to the rear right safety
sensor.
1
Connect the air supply to the air inlet fitting [1].
Verify that the Tool Release Pressure gauge [2]
read 140 - 160 psi. Adjust the knob on the back
side of the air doubler [3] if needed.
The Spindle Air Purge gauge [4] should read 45
psi whenever the spindle is in operation. Adjust
the knob on the air regulator [5] if needed.
GM-2-5AX - Installation Guide
Page 14 of 15 pages