GB
2
WARNING
The stove must not be set up to be operated jointly with the home’s air conditioning and ventilation units.
Note
Exceptions:
RLU certified appliances can also be operated with extractor hoods, vented tumble dryers and air conditioning
and ventilation units if the stove has also been connected to a balanced flue.
3. Electrical connection
• The stove is operated with a mains voltage of 230V 50Hz.
• Only use the original mains cable supplied with the appliance.
• The socket must be easily accessible.
4. Chimney
WARNING
The chimney must be made of stainless steel or ceramics (glazed inside) in order to be suitable for wet
operation, and cannot be soaked with soot. It is necessary due to the low temperature of the fumes your pellet
stove has.
WARNING
Prior to the installation, it is always necessary to calculate the chimney according to the standard.
WARNING
The minimum diameter of a chimney stack must be Ø 100 mm.
CAUTION
Please observe the national regulations.
4.1. Weather conditions
For the safe operation of the fireplace, it must be ensured that the chimney is able to build up the necessary
flue draft. Particular attention needs to be paid to this during the transition period (E.G. autumn and spring) or
during poor weather conditions (E.G. strong wind, fog etc.).