GB
17
10.7. Shut down
If a fault occurs, then a shut down is initiated. The components are switched on or off as follows:
• Induced draught fan – ON and Screw conveyor – OFF and Ignition – OFF
10.8. Cooling
The end of the shut down process depends on time and temperature.
10.9. Error display - Fault
+++ error +++
The stove can no longer be automatically started up.
The operator can see the fault on the display.
Once the fault has been properly corrected and the error message
on the operator console has been cleared, the stove can be started
up again.
Procedure:
The error is cleared by pressing the
"OK"
button.
Welcome page is displayed.
26 °C
23 °C
F018
ON/OFF
con.
Note
Otherwise please read the information under Faults, causes, correction.
10.10. OFF
11. Overheating protection
A safety temperature limiter (STL) automatically switches the stove off if it overheats. The error F001 is shown
on the console display under operating status. In this case, the appliance must be inspected by a qualified
technician!
12. Power cut
The control unit has a backup battery so that data is retained during a power cut.
A distinction is made between a short power cut and a long power cut.
Short power cut – lasts for less than about 30 seconds:
• Once the electricity supply has been restored, the stove continues its operation.
Long power cut – lasts for more than about 30 seconds:
• Once the electricity supply is restored, the stove switches to the Shut down operating status and
subsequently to "OFF".