Geräteblatt HSP 6 Pelletto-III RLU PGI
421.08

Geräteblatt

Pelletofen

DE

Fiche technique

Poêle à pellets

FR

Scheda tecnica

Stufe pellet

IT

Equipment sheet

Pellet stove

GB

Tehnički list

Kotel na pelete

HR

Tehnični list

Kotel na pelete

SLO

0542108041400c

Technische Dokumentation

Geräteblatt HSP 6 Pelletto-III RLU PGI

421.08

Содержание HSP 6 Pelletto-III RLU PGI 421.08

Страница 1: ...lletofen DE Fiche technique Po le pellets FR Scheda tecnica Stufe pellet IT Equipment sheet Pellet stove GB Tehni ki list Kotel na pelete HR Tehni ni list Kotel na pelete SLO 0542108041400c Technische...

Страница 2: ...heating device or of an injury The note entitled Notice advises you on possible damage to your heating device The note entitled Important calls your attention to the information important for the ope...

Страница 3: ...pot weekly 3 4 Maintenance work 5 4 1 Cleaning the pellet container annual maintenance 5 4 2 Cleaning the flue gas passes long time 6 5 Replacement parts list 8 5 1 Replacement parts list HSP 6 Pelle...

Страница 4: ......

Страница 5: ...Contents of storage container pellet tank about 17 kg Duration of burn with one charge min max about 10 h 30 h Permitted fuel Low dust wood pellets diameter 6 mm to Norm M 7135 DIN plus EN plus A1 le...

Страница 6: ...Dimensions 2 2 Dimensions...

Страница 7: ...the OFF operating mode 3 3 Clean combustion chamber function instruction Error F040 The whole combustion space must be cleaned after 30 hours operation at the latest or once a week The requirement to...

Страница 8: ...ing in the pellet tank might possibly result This will destroy your device and is not covered in your guarantee WARNING Cleaning the combustion pot may only be done with a cooled down stove in OFF ope...

Страница 9: ...or 3 times WARNING Devices that are not maintained in accordance with our specifications must not be operated Failure to observe this point will invalidate all guarantee claims 4 1 Cleaning the pellet...

Страница 10: ...ellets at the latest it is recommendable to check clean the conduits of combustion products the induced draught fan and the smoke flues For cleaning employ a brush or an ash exhauster Please perform t...

Страница 11: ...e cleaning as pr the Fig 3 Figure 3 Removing the side wall CAUTION After completion of the cleaning make sure that when putting back the covers the seals are seated in the right positions It is essent...

Страница 12: ...Replacement parts list 8 5 Replacement parts list 5 1 Replacement parts list HSP 6 Pelletto III 421 08 RLU PGI without trim parts...

Страница 13: ...69 12 Backup battery CR 2032 1 piece 13a Stand front 2 piece 0089501090005 13b Stand back 2 piece 0551908505005 14 Ignition 1 piece 0541908005202 15 Room temperature sensor 1 piece 0089500390005 16 Fl...

Страница 14: ...Detail A1 A1 1 Screwing door 1 piece 0541908305001 A1 2 Door hinge anthracite Set 1 piece 0541908005340 A1 3 Glass holder anthracite Set 1 piece 0551908005308 36 Combustion chamber door anthracite 1 p...

Страница 15: ...I 421 08 RLU PGI Pos Description Piece No PR Replacement parts list Pelletto III 421 08 RLU PGI 40 Side wall right grey 1 piece 0541908016150 41 Front plate anthracite 1 piece 0541908006120 42 Side wa...

Страница 16: ...arts list Pelletto III 421 08 RLU PGI 44 Side wall right anthracite 1 piece 0541908006140 45 Side part C ceramic right ahorn 1 piece 0541908016185 46 Front plate anthracite 1 piece 0541908006120 47 Si...

Страница 17: ...Circuit diagram 13 6 Circuit diagram Circuit diagram IO 33 3...

Страница 18: ...onveyor motor 7 Induced draught 8 9 OC 35 36 Flue gas temperature sensor 37 38 Flame temperature sensor 39 40 Room temperature sensor 41 42 Bottom flame temperature sensor 43 44 Door contact switch 48...