1

1. Technical data

Pallazza III 520.08
RLU–PGI

Heat output range:

2,4 – 8,3 kW

Nominal heat output:

8,0 kW

Height:

1002 mm

Width:

557 mm

Depth:

493 mm

Weight:

115 kg

Diameter of flue elbow:

80 mm

Flue gas temperature:

206 °C

Testing transport pressure at nominal output:

11 Pa

Testing transport pressure at partial output:

5 Pa

Flue gas flow rate in g/s

5,6 g/s

CO level in flue gas (%) (min./max.)

0,001/0,023 %

Efficiency:

90/95 %

CO level in flue gas:

15 mg/Nm³

NOx level in flue gas:

143/- mg/Nm³

OGC level in flue gas:

<5 mg/Nm³

Proportion of dust in flue gas:

9/- mg/Nm³

Contents of storage container (pellet tank):

about 17 kg

Duration of burn with one charge (min./max.):

about 10 h/30 h

Permitted fuel: Low-dust wood pellets

Diameter: 6 mm

to Ö-Norm M 7135, DIN plus, EN plus-A1

Length: max. 30 mm

Room heating capacity to Ö-Norm M 7521:

max. 230 m³

Room heating capacity to DIN 18893, constant heating:

250m³/145m³/98m³

Room heating capacity to DIN 18893, timed heating:

165m³/95m³/65m³

Electricity supply:

230 V (50 Hz)

Electricity supply input:

in normal operation:

max. 50 W

Electric ignition (for max. 15 minutes on ignition):

max. 380 W

Electronics fuses: (F3)

T 0,315 A, 250 V

Fuses for the ignition, screw conveyor motor, induced draught,
(F1)

T 3,12 A, 250 V

Safety distances

Minimal distances from flammable materials:

side:

15 cm

rear:

10 cm

front (radiation area):

80 cm

Содержание HSP 6 Pallazza III 520.08 RLU-PGI

Страница 1: ...HSP 6 Pallazza III 520 08 RLU PGI Equipment sheet Pellet stove GB 0552008001403a Equipment sheet HSP 6 Pallazza III 520 08 RLU PGI ...

Страница 2: ...the heating device or of an injury The note entitled Notice advises you on possible damage to your heating device The note entitled Important calls your attention to the information important for the operation of your heating device The note itself calls your attention to the information important for the operation of your heating device in general ...

Страница 3: ...struction Error F040 3 3 4 Cleaning the combustion pot weekly 3 4 Maintenance work 5 4 1 Cleaning the flue gas passes 5 4 2 Cleaning the pellet container annual maintenance 8 5 Replacement parts list 9 5 1 Replacement parts list Pallazza III 520 08 RLU PGI without trim parts 9 5 2 Detail A1 11 5 3 Replacement parts list Pallazza III 520 08 RLU PGI 12 6 Circuit diagram 13 ...

Страница 4: ......

Страница 5: ...ontents of storage container pellet tank about 17 kg Duration of burn with one charge min max about 10 h 30 h Permitted fuel Low dust wood pellets Diameter 6 mm to Ö Norm M 7135 DIN plus EN plus A1 Length max 30 mm Room heating capacity to Ö Norm M 7521 max 230 m Room heating capacity to DIN 18893 constant heating 250m 145m 98m Room heating capacity to DIN 18893 timed heating 165m 95m 65m Electric...

Страница 6: ...Dimensions GB 2 2 Dimensions ...

Страница 7: ...ustion chamber function instruction Error F040 The whole combustion space must be cleaned after 30 hours operation at the latest or once a week The requirement to clean the fire box flickering of the display appears during heating in case that the cleaning interval has elapsed After the fire box has been cleaned the error message Clean the fire box will be confirmed automatically The condition for...

Страница 8: ...ering in the pellet tank might possibly result This will destroy your device and is not covered in your guarantee WARNING Cleaning the combustion pot may only be done with a cooled down stove in OFF operating mode Otherwise there is a risk of burns Take out the burner bowl from the stove Remove the remains of ashes and slag After the cleaning mount the burner bowl back to its proper position on th...

Страница 9: ...h content is higher 0 5 and over the interval from maintenance to maintenance is reduced and the accumulation of ash increases by 2 or 3 times WARNING Devices that are not maintained in accordance with our specifications must not be operated Failure to observe this point will invalidate all guarantee claims 4 1 Cleaning the flue gas passes CAUTION Check and clean the flue gas ways exhaust flue gas...

Страница 10: ...Maintenance work GB 6 Figure 1 Removing the flue baffle ...

Страница 11: ...work GB 7 Figure 2 Removing the side wall CAUTION After completion of the cleaning make sure that when putting back the covers the seals are seated in the right positions It is essential to replace defective seals ...

Страница 12: ... 1 in the pellet tank may be removed Then clean the tank and the intake of the screw conveyor housing with a vacuum cleaner After cleaning it is essential to put back the protective grille When doing this make sure that no screws fall into the pellet tank so as to avoid consequential damage to the screw conveyor Figure 3 Pellet tank 1 Protective grille 2 Tank cover ...

Страница 13: ...Replacement parts list GB 9 5 Replacement parts list 5 1 Replacement parts list Pallazza III 520 08 RLU PGI without trim parts ...

Страница 14: ...attery CR 2032 1 piece 13 Stand 4 piece 0551908505005 14a Ignition 1 piece 0541908005202 14b Lighter case 1 piece 0553808005215 15 Room temperature sensor 1 piece 0089500390005 16 Flue gas thermosensor 1 piece 0561008005540 17 OC 1 piece 0089500080005 18 Cover hinge pins DIN 427 M5x18 1 piece 0551908005015 19 Protective grille 1 piece 0551908005931 20 Closure frame 1 piece 0551908005160 21 Framewo...

Страница 15: ...5 37 Screw UN5950 M5x10 4 piece 38 Air hose 1 piece 0551908015315 5 2 Detail A1 Pos Description Piece No PR Detail A1 A1 1 Screwing door Set 1 piece 0551908005001 A1 2 Door hinge Set 1 piece 0551908005002 A1 3 Glass holder Set 1 piece 0551908005003 39 Combustion chamber door black 1 piece 0551908007201 40 Seal glass 10x4 mm 900 mm 1 piece 0040210040005 ...

Страница 16: ... III 520 08 RLU PGI 43 Side wall rear right antracite 1 piece 0551908015510 44 Side wall middle right black 1 piece 0551908016400 45 Side wall front right antracite 1 piece 0551908026300 46 Front plate black anthracite 1 piece 0551908116200 47 Side wall rear left antracite 1 piece 0551908015511 48 Side wall middle left black 1 piece 0551908016410 49 Side wall front left antracite 1 piece 055190802...

Страница 17: ...Circuit diagram GB 13 6 Circuit diagram Circuit diagram IO 33 3 ...

Страница 18: ...conveyor motor 7 Induced draught 8 9 OC 35 36 Flue gas temperature sensor 37 38 Flame temperature sensor 39 40 Room temperature sensor 41 42 Bottom flame temperature sensor 43 44 Door contact switch 48 50 Flue gas fan rotation speed F1 Fuse T 3 15 A ignition induced draught fan screw conveyor motor F3 Fuse T 0 315 A operator console ...

Страница 19: ......

Отзывы: