![Haas+Sohn VIKING 75 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/haas-sohn-0/viking-75/viking-75_installation-and-maintenance-instructions-manual_3122439010.webp)
----------------------------------------------------------------------------
Installation instructions
----------------------------------------------------------------------------
When installing the stove
all regulations
concerning building and fire safety are to be
observed.
If the stove is placed on a floor made of flammable
materials such as wood or plastic, then the floor
panel is to be attached. This panel projects beyond
the stove by at least 10 cm at the sides and at
least 50 cm at the front.
The stove supply pressure must not be
below 0.12 mbar.
Horizontal exhaust gas pipes over 0.5 m long must
rise towards the chimney connection at 10°
degrees. Pipes that are not heat insulated or
installed vertically may not be longer than 1.25 m.
The diameter of the exhaust gas pipe from the
exhaust gas connector to the chimney may not be
reduced.
ATTENTION!! The minimum spacing
between the stove or exhaust gas pipe and flammable or temperature-sensitive materials or
pieces of furniture must be 20 cm and absolutely must be observed! (See Accessories).
------------------------------------------------------------------------------
Exhaust gas connector
------------------------------------------------------------------------------
If the exhaust gas pipe is to be fitted on the side:
Remove the relevant side wall after undoing the fixing screws. To
do this, unscrew the enamelled cover panel from the side wall.
Undo the screws and remove the cover from the connection
opening.
Then attach the exhaust gas connector and after turning it to the left,
tighten the screw. Reattach the side wall.
If the exhaust gas pipe is to be fitted to the back of the stove:
Fit the exhaust gas connector as described for the side connection.