6
Installation instructions
When installing the stove, all legal and
relevant fire safety regulations must be
observed.
If the stove is installed on a flammable
material like for example wood, then a
bottom plate has to be attached which
overlaps the device minimum 10 cm
laterally and minimum 50 cm forward.
The delivery pressure of the chimney
must not be less than 0.12 mbar.
Horizontal exhaust pipes over 0,5
m length have to enter the flue
connection at maximum 10
degrees. Pipes that are not heat
insulated or are not vertical should
not be longer than 1,25 m.
The diameter of the exhaust pipe
from the flue outlet to the chimney
must not be reduced.
Available as accessory:
1 Spacer ledge
– is externally fitted
on the enamelled side wall.
ATTENTION! The minimum distance between the stove, exhaust pipe
and flammable or temperature-sensitive materials, respectively
furniture elements has to be 20 cm and must be adhered to! (See
accessories).
Exhaust stack
The exhaust pipe is to be
mounted on the side:
Remove the appropriate side panel
after loosening the mounting
screws. Unscrew the enamelled
sealing cap from the side wall.
Loosen the screws and remove the
cover front of the connection opening.
Then attach the exhaust outlet and
tighten the screw into the left. Install
sidewall again.
The exhaust pipe is to be mounted on
the rear:
Fit the flue outlet (see second
paragraph) as described for the
connection to the side.