GB
6
WARNING
During the operation regime of heating, the lever must not be set to "Shut input of air" "0"; it could bring about
a sudden inflammation of fuel.
5.4.1.1. Ignition - London II, Hillington, Kensington, Fulham, Westminster
• First of all, lay logs according to their size (about 1.5 – 2.0 kg) on the bottom of the combustion space or on
the grate, lay on them a block of solid fire-brand, and on the top, sufficient amount of kindling chip (for
ignition). The indicated amount of wood refers to the first ignition ONLY.
• The lever must be set up to "Ignition "START". After the ignition, the door of the combustion chamber is to
be closed.
• The course of ignition depends on the draft of the chimney. As soon as complete fuel starts burning lively,
the lever is to be re-set to "Heating".
Ignition
Heating
Shut input of air
WARNING
During the operation regime of heating, the lever must not be set to "Shut input of air" "0"; it could bring about
a sudden inflammation of fuel.
5.4.2. Ignition without the air control EASY CONTROL
• First, insert chunks onto the bottom of combustion chamber or onto the grid, by size (approx. 1.5 to 2.0 kg).
Then, put a solid fire-lighter cube on the chunks, and a small amount of fine wood onto the top. The above
mentioned amount of the wood is ONLY for heating.
• All air slide valves (primary and secondary air regulators) must be fully opened. After flooding, the
combustion chamber door must be closed. The heating process depends on the draft of the chimney. Once
the complete fuel starts to burn, the "Primary Air Regulator" slide valve must be closed.