![H3C WBC580 G2 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/h3c/wbc580-g2/wbc580-g2_installation-manual_3119701010.webp)
3
•
Carefully examine your work area for possible hazards, such as moist floors.
•
Locate the emergency power-off switch in the room before installation. Shut off the power
immediately if an accident occurs. Remove the power cord if necessary.
•
Do not work alone when you operate the device with power on.
•
Always verify that the power has been disconnected when you perform operations that require
the device to be powered off.
•
To avoid device damage or bodily injury, use the power cord supplied with the device.
•
Do not use the supplied power cord on any other devices.
•
Power off the device before installing or removing any non-hot-swappable hardware options.
Laser safety
WARNING!
•
Disconnected optical fibers or transceiver modules might emit invisible laser light. Do not stare
into beams or view directly with optical instruments when the router is operating.
•
Before you remove the optical fiber connector from a fiber port, execute the
shutdown
command in interface view to shut down the port.
CAUTION:
•
Install dust caps for open optical fiber connectors to protect them from contamination and ESD
damage.
•
Insert dust plugs into open fiber ports and transceiver module ports to protect them from
contamination and ESD damage.
Examining the installation site
The device can only be used indoors. For the device to operate correctly and have a prolonged
service time, the installation site must meet the following requirements.
Temperature and humidity
Make sure the temperature and humidity in the equipment room meet the requirements described in
•
Lasting high relative humidity can cause poor insulation, electricity leakage, mechanical
property change of materials, and metal corrosion.
•
Lasting low relative humidity can cause washer contraction and ESD and cause problems
including loose mounting screws and circuit failure.
•
High temperature can accelerate the aging of insulation materials and significantly lower the
reliability and lifespan of the device.
Table1-2 Temperature and humidity requirements for the equipment room
Temperature
Humidity
•
Operating temperature: 5°C to 45°C (32°F to
113°F)
•
Storage temperature: –40°C to +70°C (–40°F to
+158°F)
•
Operating humidity: 8% RH to 90% RH,
noncondensing
•
Storage humidity: 5% RH to 95% RH,