2-4 

Mounting the AP on a ceiling 

 

CAUTION: 

The ceiling for installing the AP must be less than 18 mm (0.71 in) in thickness, and can bear a load 
of 5 kg (11.02 lb). If you must install the AP on a ceiling not strong enough, use boards to reinforce 
the ceiling. 

 

To mount the AP on a ceiling: 

1. 

Remove the ceiling tile. 

2. 

Place the mounting bracket against the ceiling tile and mark the installation holes on the ceiling 
tile.Drill three holes with a diameter of 6 mm (0.24 in) at the marked positions, as shown 
in 

Figure2-7

Figure2-7 Drilling holes in the ceiling tile 

 

 

3. 

Thread the pan-head screws through the installation holes in the mounting bracket and into the 
holes in the ceiling tile. Fasten washers and nuts at the other side of the ceiling to secure the 
mounting bracket to the ceiling, as shown in 

Figure2-8

Figure2-8 Attaching the mounting bracket to the ceiling 

 

 

4. 

Position the four pegs on the AP into the keyhole slots in the mounting bracket and slide the 
AP until it clicks into place, as shown in 

Figure2-9

Содержание WA6330

Страница 1: ...lation tasks 2 1 Determining the installation position 2 1 Mounting the AP 2 2 Mounting the AP on a wall 2 2 Mounting the AP on a ceiling 2 4 Connecting the AP to a power source 2 5 Connecting a PoE power source 2 5 Connecting a local power source 2 6 Check after power on 2 6 Connecting the AP to the network 2 6 3 Appendix A Technical specifications 3 1 4 Appendix B Ports and LEDs 4 1 Ports 4 1 LE...

Страница 2: ...y and flat location and take anti slip measures Keep the AP clean and dust free Do not place the AP in a moist area and avoid liquid intrusion Keep the AP and installation tools away from walkways Site preparation Before installing the AP examine the installation site and ensure that the AP will operate in a favorable environment Make sure the temperate and humidity at the installation site meets ...

Страница 3: ...1 2 Installation tools When installing the AP you might need the following tools Prepare the installation tools yourself as required Figure1 2 Installation tools ...

Страница 4: ... use Make sure you have completed cabling at the installation site Determining the installation position Determine the installation position by observing the following principles Few obstacles such as wall exist between the AP and clients The AP is far away from electronic devices such as microwave oven that might generate radio frequency RF noise The AP does not hinder people s daily work and lif...

Страница 5: ...ainst the wall and mark the installation holes on the wall Figure2 2 Marking the installation holes on the wall 2 Drill holes with a diameter of 6 mm 0 24 in and a depth of 30 mm 1 18 in at the marked locations as shown in Figure2 3 Figure2 3 Drilling holes in the wall 3 Insert a screw anchor into each hole and tap the screw anchor with a rubber hammer until it is all flush with the wall surface a...

Страница 6: ...les in the wall Fasten the screws to secure the mounting bracket to the wall Figure2 5 Attaching the mounting bracket to the wall 5 Position the four pegs on the AP into the keyhole slots in the mounting bracket and then slide the AP down until it clicks into place as shown in Figure2 6 Figure2 6 Attaching the AP to the mounting bracket ...

Страница 7: ...iling tile Drill three holes with a diameter of 6 mm 0 24 in at the marked positions as shown in Figure2 7 Figure2 7 Drilling holes in the ceiling tile 3 Thread the pan head screws through the installation holes in the mounting bracket and into the holes in the ceiling tile Fasten washers and nuts at the other side of the ceiling to secure the mounting bracket to the ceiling as shown in Figure2 8 ...

Страница 8: ... AP You can supply power to the AP by using a local power source or through 802 3af 802 at PoE as required Before powering the AP make sure the power source the local power source or the PSE is reliably grounded Connecting a PoE power source CAUTION The AP is to be connected only to PoE networks without routing to the outside plant To power the AP through PoE use an Ethernet cable to connect an Et...

Страница 9: ... For more information about AP LEDs see LEDs Connecting the AP to the network All AP settings are configured on the AC To verify the network connectivity of the AP execute the display wlan ap all command on the AC If the AP status is R M the AP has been connected to the network Sysname display wlan ap all Total number of APs 1 Total number of connected APs 1 Total number of connected manual APs 1 ...

Страница 10: ...2 7 AP name APID State Model Serial ID ap1 1 R WA6330 219801A23V8192E00021 ...

Страница 11: ... oz Antenna built in 2 4 G gain of 3 dBi 5 G gain of 5 dBi System power consumption 16 5 W not supplying PoE power 32 W supplying PoE power 12 93 W Not supplying PoE power and with the radios operating in 1 1 MIMO mode Powering option Local DC power source 802 3at PoE the system power consumption 16 5 W 802 3af PoE the system power consumption 12 93 W Protocol 802 11b g a n ac ax 802 3at af ...

Страница 12: ...4 1 Port and button descriptions Port Standards and protocols Description Reset button N A To reset the AP press and hold the button for no more than 5 seconds To restore the factory default press and hold the button for more than 5 seconds Console port RS EIA 232 Used for device configuration and management only USB port USB 2 0 N A 10 100 1000M Ethernet copper port GE PSE IEEE802 3 IEEE802 3u IE...

Страница 13: ... Off No power is present or the LED has been turned off from the CLI Yellow Steady on The AP is initializing or an initialization exception has occurred Flashing at 1 Hz No radio cards have been detected Flashing at 2 Hz The Ethernet interfaces are down and no mesh links are established Green Steady on The AP has registered to an AC but does not have any associated clients Flashing at 0 5 Hz The A...

Отзывы: