Figure 2 Attaching the mounting bracket to an electrical outlet box 

 

 

Connecting cables 

Connect the network cable from the box to the Uplink/PoE In port on the rear of the AP. Connect a 
cable to the Pass Through port on the rear of the AP as required. 

 

 

NOTE: 

The Pass Through ports on the rear and right side of the AP are standard RJ-45 ports. You can 
connect telephone cables or other cables to them as needed. 

 

Figure 3 Connecting cables 

 

 

Содержание WA510H

Страница 1: ...H3C WA510H Access Point Installation Guide New H3C Technologies Co Ltd http www h3c com Document version 6W101 20190527 ...

Страница 2: ...r respective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be accurate but they are presented without warranty of any kind express or implied H3C shall not be liable for technical or editorial errors or omissions contained herein Environmental protection This prod...

Страница 3: ...t are optional x y Braces enclose a set of required syntax choices separated by vertical bars from which you select one x y Square brackets enclose a set of optional syntax choices separated by vertical bars from which you select one or none x y Asterisk marked braces enclose a set of required syntax choices separated by vertical bars from which you select a minimum of one x y Asterisk marked squa...

Страница 4: ...as a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Represents an access controller a unified wired WLAN module or the access controller engine on a unified wired WLAN switch Represents an access point Represents a wireless terminator unit Represents a wireless terminator Represents a mesh access point Represents omnidirectional signals Represents...

Страница 5: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments ...

Страница 6: ...Installing the AP 3 Attaching the mounting bracket to an electrical outlet box 3 Connecting cables 4 Installing the AP 5 Connecting the AP to the power supply 6 Check before power on 6 Connecting the PoE power supply 6 Connecting the local power supply 7 PoE injector power supply 8 Check after power on 8 Connecting the AP to the network 8 Appendix A Technical specifications 10 Appendix B LEDs and ...

Страница 7: ...e AP in a dry and flat location and take anti slip measures Keep the AP clean and dust free Do not place the AP in a moist area and avoid any liquid intrusion Keep the AP and installation tools away from walkways Temperature and humidity requirements Item Specification Operating temperature 0 C to 40 C 32 F to 104 F Storage temperature 40 C to 70 C 40 F to 158 F Operating humidity noncondensing 5 ...

Страница 8: ...n tools and equipment When installing the AP you might need the following tools Prepare these tools and equipment yourself Phillips screwdriver Needle nose pliers Wire stripping pliers Torx screwdriver Wire crimper ...

Страница 9: ...mine the LEDs to verify that the AP can operate correctly For more information about AP LEDs see Appendix B LEDs and ports Record the AP MAC address and serial number marked on the rear of the AP for future use Installing the AP Attaching the mounting bracket to an electrical outlet box As shown in Figure 2 use the M4 screws to attach the mounting bracket to an electrical outlet box ...

Страница 10: ...om the box to the Uplink PoE In port on the rear of the AP Connect a cable to the Pass Through port on the rear of the AP as required NOTE The Pass Through ports on the rear and right side of the AP are standard RJ 45 ports You can connect telephone cables or other cables to them as needed Figure 3 Connecting cables ...

Страница 11: ...ndout on the mounting bracket Figure 4 Aligning the AP installation hole with the mounting bracket standout 2 Push the AP onto the mounting bracket and then slide it down until it is fully engaged Then secure the AP to the bracket by using the M2 9 4 security screw as shown in Figure 5 ...

Страница 12: ... before powering on the AP To power the AP with local power make sure the local power supply is reliably grounded To power the AP through PoE make sure the PoE power supply PSE is reliably grounded To power the AP through PoE injector make sure the PoE power supply PSE is reliably grounded Connecting the PoE power supply Use a network cable to connect the Uplink PoE In port on the AP to a switch t...

Страница 13: ...st be ordered separately Table 1 Power adapter specifications Item Specification Input 100 VAC to 240 VAC Output 54 VDC at 0 74 A You can power the AP by using an power adapter Use the power adapter to connect the power port of the AP to the local power source Figure 7 Connecting the local power supply ...

Страница 14: ...ion about AP LEDs see Appendix B LEDs and ports Connecting the AP to the network For Internet or MAN access connect an Ethernet port on the AP to an Ethernet port on an Ethernet switch and then verify that the AP has been connected to the network The AP can only act as a fit AP and all fit AP settings are configured on the AC Execute the display wlan ap all command on the AC that connects to the f...

Страница 15: ...erver AP licenses 0 Remaining local AP licenses 127 Sync AP licenses 0 AP information State I Idle J Join JA JoinAck IL ImageLoad C Config DC DataCheck R Run M Master B Backup AP name AP ID State Model Serial ID ap1 1 R M WA510H 219801A1NS8182032235 ...

Страница 16: ...fications Item Specification Protocol IEEE802 11a b g n ac Wave2 Radio Two Dimensions H W D 150 86 36 8 mm 5 91 3 39 1 45 in Weight 250 g 0 55 lb Built in antenna 2 4 G antenna 3 46 dBi peak gain 5 G antenna 3 40 dBi peak gain Maximum power consumption 12 95 W ...

Страница 17: ...2 Hz The Ethernet interfaces are shut down and no mesh link is present Flashing green 0 5 Hz The AP has started up but is not connected to any AC Flashing green 2 Hz The AP is updating applications Steady green The AP is operating correctly Radio LED Off No clients are associated with the AP or the LED is disabled from the CLI Flashing green 1 Hz The 2 4 G radio has associated clients Flashing yel...

Страница 18: ...ps Ethernet port LED Off No link is present on the port Steady yellow The negotiated rate is 10 100 Mbps Flashing yellow The Ethernet port is sending or receiving data at 10 100 Mbps Steady green The negotiated rate is 1000 Mbps Flashing green The Ethernet port is sending or receiving data at 1000 Mbps Ports The AP provides the following ports One console port Four 10 100 1000 Mbps copper Ethernet...

Страница 19: ...u IEEE802 3af The 10 100 1000 Mbps copper Ethernet port acts as a downlink interface Ports 1 through 4 are represented by GE1 0 2 through GE1 0 5 respectively Uplink PoE In IEEE802 3 IEEE802 3u IEEE802 3af The 10 100 1000 Mbps copper Ethernet port can act as an uplink interface connecting to Internet or MAN and receive PoE power supply at the same time It is represented by interface GE1 0 1 DC 54V...