Preparing for installation 

Safety recommendations 

 

CAUTION: 

 

Install the AP under instruction of professional engineers.  

 

Read the following safety recommendations before installation. 

 

To avoid possible bodily injury and equipment damage, read the following safety recommendations 

before installing the AP. Note that the recommendations do not cover every possible hazardous 

condition. 

 

Take adequate safety measures to avoid injury and AP damage. 

 

The installation site has a flat and dry ground and anti-slip measures are in place. 

 

Keep the AP clean and dust-free. 

 

Do not place the AP in a moist area and avoid liquid surrounding the AP. 

 

Keep the AP and installation tools away from walkways. 

Temperature and humidity requirements 

Item Specification 

Operating temperature (indoor)

 

0°C to 45°C (32°F to 113°F) 

Storage temperature

 

–40°C to +70°C (–40°F to +158°F) 

Operating humidity (noncondensing)

 

5% to 95% 

 

Accessories provided with the AP 

 x 2 

 x 1 

Wall anchor kit (expansion anchor and screw) 

T6 Torx screw 

 x 2 

 x 1 

Ceiling mount kit (pan-head screw, washer, and nut) 

AC/DC adapter 

 

Содержание WA4320-ACN-PI

Страница 1: ... with the AP 3 Installation tools and equipment 4 Installing the AP 5 Checking before installation 5 Determining the installation position 5 Installing the AP 6 Mounting the AP on a wall 6 Mounting the AP on a ceiling 9 Powering the AP 11 Connecting the AP to the local power supply 11 Connecting the AP to the network 12 Logging in to the AP 13 ...

Страница 2: ...wireless switches or access controllers The H3C WA4320 ACN PI can also act as a fat AP to provide wireless access for WLAN users Figure 1 Deployment of the WA4320 ACN PI as a fit AP at hotspots Core equipment room RADIUS server Wireless NMS Switch Switch Switch Switch Switch Meeting room Restaurant or tea house Hall or information desk Parking lot PC PC PC PC AC WA4320 ACN PI WA4320 ACN PI WA4320 ...

Страница 3: ...tenna 2 4 G antenna 3 dBi gain 5 G antenna 5 dBi gain Power consumption 3 5 W to 8 W Dimensions H W D 133 1 90 24 6 mm 5 24 3 54 0 97 in Weight 0 15 kg 0 33 lb Core equipment room RADIUS server Wireless NMS Switch Switch Switch Switch Switch Meeting room Restaurant or tea house Hall or information desk Parking lot PC PC PC PC WA4320 ACN PI WA4320 ACN PI WA4320 ACN PI WA4320 ACN PI ...

Страница 4: ...y and AP damage The installation site has a flat and dry ground and anti slip measures are in place Keep the AP clean and dust free Do not place the AP in a moist area and avoid liquid surrounding the AP Keep the AP and installation tools away from walkways Temperature and humidity requirements Item Specification Operating temperature indoor 0 C to 45 C 32 F to 113 F Storage temperature 40 C to 70...

Страница 5: ...nd equipment When installing the AP you may need the following tools and equipment Prepare these tools and equipment yourself Phillips screwdriver T10 Torx screwdriver Rubber hammer Percussion drill with drills Marker Ladder ...

Страница 6: ...s been completed at the installation site Record the AP MAC address and serial number marked at the rear of the AP for future use Determining the installation position Determine the installation position by observing the following principles Few obstacles such as walls exist between the AP and the clients The AP is far away from electronic devices such as microwave oven that might generate radio f...

Страница 7: ...e 4 Marking two installation points on the wall 2 Attach the wall anchor kit to the wall a Insert an expansion anchor into each hole and use a rubber hammer to tap the expansion anchor until the anchor is all flush with the wall surface b Fasten the screw into each expansion anchor Do not fasten the screw all the way into the anchor and leave 2 5 mm 0 10 in to 4 5 mm 0 18 in of the screw exposed ...

Страница 8: ...e wall 1 Expansion anchor 2 Screw 3 Attach the AP to the wall a Align the mounting holes in the AP with the screws as shown by callout 1 in Figure 6 b Slide the AP down to secure the AP in place by using the screws as shown by callout 2 in Figure 6 ...

Страница 9: ...8 Figure 6 Attaching the AP to the wall 4 Align the T6 security Torx screw with the screw hole in the AP right Use the T10 Torx screwdriver to fasten the T6 Torx screw See Figure 7 ...

Страница 10: ... 18 mm 0 71 in in thickness and can bear a load of 5 kg 11 02 lb H3C recommends that you reinforce the ceiling by using boards if the ceiling is not strong enough To install the AP on a ceiling 1 Mark two installation points on the ceiling as shown in Figure 4 2 Drill holes with a diameter of 5 0 mm 0 20 in at the marked points as shown in Figure 8 ...

Страница 11: ...re 9 Attaching the ceiling mount kit to the ceiling 4 Connect the AP to the LAN by using Ethernet cables 5 Attach the AP to the ceiling a Align the mounting holes of the AP with the screws as shown by callout 1 in Figure 10 b Slide the AP forward to secure the AP in place by using the screws as shown by callout 2 in Figure 10 c Align the T6 security Torx screw with the screw hole in the AP right a...

Страница 12: ...ingle phase three wire system 100 V to 240 V 50 60 Hz NOTE If the local power supply is not stable in voltage use voltage adjusting or controlling device to ensure that the voltage fluctuation is in the acceptable range To ensure uninterrupted services use a UPS Connecting the AP to the local power supply Before connecting the AP to the local AC power supply make sure the local AC power supply is ...

Страница 13: ...onnected to the network When the AP operates as a fit AP execute the display wlan ap all command on the AC that connects to the fit AP If the AP status is R M the AP is connected to the network AC display wlan ap all Total Number of APs configured 1 Total Number of configured APs connected 1 Total Number of auto APs connected 0 AP Profiles State I Idle J Join JA JoinAck IL ImageLoad C Config R Run...

Страница 14: ...re you log in to the fat AP through Telnet or Web obtain the IP address of the AP first By default Telnet login and Web login are enabled You can log in to the AP through Telnet or Web by using the following default login information Username admin Password h3capadmin IP address of VLAN interface 1 of the AP 192 168 0 50 with subnet mask 255 255 255 0 If the default IP address is changed contact t...

Отзывы: