57
Figure 70 Installing the riser card
8.
Connect cables for the GPU module as needed.
9.
Install the access panel. For more information, see "
10.
Rack-mount the server. For more information, see "
11.
Connect the power cord. For more information, see "
12.
Power on the server. For more information, see "
Verifying the installation
Log in to HDM to verify that the GPU module is operating correctly. For more information, see HDM
online help.
Installing a GPU module with a power cord (standard chassis
air baffle)
To install a GPU-K80-1, GPU-M60-1-X, GPU-P40-X, or GPU-M10-X, make sure all the six fans are
present before you power on the server.
The procedure is the same for installing a GPU module in riser cards on PCIe riser connectors 1, 2,
and 3. This section uses the GPU-M4000-1-X and PCIe riser connector 1 as an example.
Procedure
1.
Determine the installation position. For more information, see "GPU module and riser card
compatibility."
2.
Power off the server. For more information, see "
3.
Remove the server from the rack. For more information, see "
Removing the server from a rack
."
4.
Remove the access panel. For more information, see "
."
5.
Remove the PCIe riser card blank from PCIe riser connector 1, as shown in
.
6.
Remove the screw from the target PCIe slot, and then pull the blank out of the slot, as shown
in
7.
Attach the support bracket provided with the GPU module to the GPU module. As shown
in
, align screw holes in the support bracket with the installation holes in the GPU
module, and use screws to attach the support bracket to the GPU module.