144
9.
Rack-mount the server. For more information, see "
10.
Connect the power cord. For more information, see "
11.
Power on the server. For more information, see "
Verifying the replacement
Log in to HDM to verity that the drive backplanes are in a correct state. For more information, see
HDM online help.
Replacing the SATA optical drive
WARNING!
To avoid bodily injury from hot surfaces, allow the server and its internal modules to cool before
touching them.
To replace the SATA optical drive:
1.
Power off the server. For more information, see "
2.
Remove the server from the rack. For more information, see "
Removing the server from a rack
."
3.
Remove the access panel. For more information, see "
."
4.
Remove the chassis air baffle. For more information, see "
5.
Remove the fan cage. For more information, see "
."
6.
Remove the security bezel, if any. For more information, see "
7.
Disconnect the cable from the optical drive.
8.
Remove the screw that secures the optical drive, and then push the optical drive out of the slot
from the inside of the chassis, as shown in
.
Figure 180 Removing the SATA optical drive
9.
Install a new SATA optical drive. For more information, see "
Installing a SATA optical drive
."
10.
Connect the optical drive cable.
11.
Install the removed security bezel. For more information, see "
12.
Install the fan cage. For more information, see "
."