101
•
H3C is not liable for blocked data access caused by improper use of the TCM or TPM. For more
information, see the encryption technology feature documentation provided by the operating
system.
Prerequisites
Take the following ESD prevention measures:
•
Wear antistatic clothing.
•
Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
•
Do not wear any conductive objects, such as jewelry or watches.
When you replace a component, examine the slot and connector for damages. Make sure the pins
are not damaged (bent for example) and do not contain any foreign objects.
Installing a TCM or TPM
1.
Power off the server. For more information, see "
2.
Remove the server from the rack. For more information, see "
Removing the server from a rack
3.
Remove the access panel. For more information, see "
4.
Remove all riser cards that hider the installation, if any.
5.
Install the TCM or TPM.
The installation procedure is the same for a TPM and a TCM. The following information uses a
TPM to show the procedure:
a.
Press the TPM into the TPM connector on the system board, as shown by callout 1 in
b.
Insert the rivet pin, as shown by callout 2 in
c.
Insert the security rivet into the hole in the rivet pin and press the security rivet until it is
firmly seated, as shown by callout 3 in
Figure 116 Installing the TPM module
6.
Install the removed riser cards, if any.