Operating mode
Description
system.
HBA
RAID functions are disabled. Raw physical drives are exposed to the system.
Before setting this mode, you must delete all RAID arrays and hot spare
drives, and perform the
Auto Volume
In this mode, raw physical drives with system partitions are exposed to the
system, and physical drives without system partitions are configured as
simple volumes. Before setting this mode, you must delete all RAID arrays
and hot spare drives in the system.
Simple Volume
In this mode, only non-redundant RAID arrays with the simple volume level
(each contains only one drive) can be created. RAID arrays with other RAID
levels cannot be created. Before setting this mode, you must delete all RAID
arrays and hot spare drives in the system.
Scanning drives
The storage controller might fail to timely recognize drives after the drives are hot swapped. To
solve this problem, you can scan drives.
To scan drives:
1.
On the storage controller configuration screen as shown in
, select
Logical Device
Configuration
, and press
Enter
.
Figure 10 Storage controller configuration screen
2.
On the screen as shown in
, select
Rescan Drives
, and press
Enter
to scan drives.
Содержание UniServer E3200 G3
Страница 35: ...19 Figure 29 Selecting the RAID volume to be deleted...
Страница 116: ...56 Figure 96 Controller Configuration screen...
Страница 220: ...61 Figure 109 Selecting Main Menu 2 Select Controller Management and press Enter...
Страница 243: ...84 Figure 153 Confirming the operation...
Страница 293: ...50 Figure 89 Clearing completion...
Страница 382: ...21 Figure 27 Storage controller information...
Страница 389: ...7 Figure 8 Identifying a storage controller 2...