Manual version: 6PW101-20141219
BOM: 3123A0DY
iv
LED Status Description
GE/Combo copper
port
(LINK/ACT)
Off
No link is present on the port.
Steady green
A link is present on the port.
Flashing yellow
The port is sending or receiving data.
System LED(RUN)
Off
No power is input, or the card is faulty.
Steady green
The system is not operating correctly.
Flashing green (1 Hz) The system has started up and is operating correctly.
Flashing green (8 Hz) The system is loading the software or is not ready.
5
Installing and removing the card
CAUTION:
•
Wear a well-grounded ESD wrist strap or ESD gloves before you install or remove the card.
•
Do not touch the components on the PCB.
5.1
Installing the card
1.
Locate the slot where you will install the SPE-FWM-200, and remove the blank panel from the
position. This manual describes installing the SPE-FWM-200 to slot 2.
2.
Push the module with the components facing upward into the slot along the guide rails until the
positioning hole of the module is seated onto the positioning pin on the backplane. Push the ejector
levers inward to lock the module in place.
3.
Fasten the captive screws on the module with a Philips screwdriver.
Figure 2 Installing the card
5.2
Removing the card
1.
Use a Phillips screwdriver to loosen the captive screws at both sides of the card.