H3C SR6600 SPE-FWM-200 Скачать руководство пользователя страница 4

Manual version: 6PW101-20141219 

BOM: 3123A0DY

 

iv 

LED Status Description 

GE/Combo copper 
port 
(LINK/ACT) 

Off 

No link is present on the port. 

Steady green 

A link is present on the port. 

Flashing yellow 

The port is sending or receiving data. 

System LED(RUN) 

Off 

No power is input, or the card is faulty. 

Steady green 

The system is not operating correctly. 

Flashing green (1 Hz)  The system has started up and is operating correctly. 

Flashing green (8 Hz)  The system is loading the software or is not ready. 

 

 

Installing and removing the card 

 

CAUTION: 

 

Wear a well-grounded ESD wrist strap or ESD gloves before you install or remove the card. 

 

Do not touch the components on the PCB. 

 

5.1 

 

Installing the card 

1.

 

Locate the slot where you will install the SPE-FWM-200, and remove the blank panel from the 
position. This manual describes installing the SPE-FWM-200 to slot 2. 

2.

 

Push the module with the components facing upward into the slot along the guide rails until the 
positioning hole of the module is seated onto the positioning pin on the backplane. Push the ejector 
levers inward to lock the module in place. 

3.

 

Fasten the captive screws on the module with a Philips screwdriver. 

Figure 2 Installing the card 

 

 

5.2 

 

Removing the card 

1.

 

Use a Phillips screwdriver to loosen the captive screws at both sides of the card. 

Содержание SR6600 SPE-FWM-200

Страница 1: ...nsole port CONSOLE 5 USB interface 1 reserved 6 USB interface 0 reserved 7 Management Ethernet interface 1 10 100 1000BASE T 8 Management Ethernet interface 0 10 100 1000BASE T 9 Management Ethernet interface 1 LED LINK 10 Management Ethernet interface 1 LED ACT 11 Management Ethernet interface 0 LED LINK 12 Management Ethernet interface 0 LED ACT 13 Management interface 3 Electrical port of combo...

Страница 2: ...t operating 40 C to 70 C 40 F to 158 F Ambient relative humidity Operating 10 to 95 noncondensing Non operating 5 to 95 noncondensing Compatible device models H3C SR6600 routers System software version See the release notes that come with the card Table 2 Console port specifications Item Specification Connector RJ 45 Interface standard RS 232 Transmission baud rate 9600 bps default to 115200 bps T...

Страница 3: ...km 0 34 miles SFP GE LX SM1310 A 1310 nm LC 9 125 μm single mode optical fiber 10 km 6 21 miles SFP GE LH40 SM1310 1310 nm LC 9 125 μm single mode optical fiber 40 km 24 86 miles SFP GE LH40 SM1550 1550 nm LC 9 125 μm single mode optical fiber 40 km 24 86 miles SFP GE LH70 SM1550 1550 nm LC 9 125 μm single mode optical fiber 70 km 43 5 miles SFP GE LH100 SM1550 1550 nm LC 9 125 μm single mode opti...

Страница 4: ...rounded ESD wrist strap or ESD gloves before you install or remove the card Do not touch the components on the PCB 5 1 Installing the card 1 Locate the slot where you will install the SPE FWM 200 and remove the blank panel from the position This manual describes installing the SPE FWM 200 to slot 2 2 Push the module with the components facing upward into the slot along the guide rails until the po...

Страница 5: ...all Cards Configuration Guide To log in to the card from the router s CLI perform the following task in user view Task Command Remarks Log in to the card through OAP In standalone mode oap connect slot slot number In IRF mode oap connect chassis chassis number slot slot number To return to the CLI interface of the router press Ctrl K 7 Software upgrade The card uses independent BootWare and system...

Отзывы: