H3C SecPath NSQM2GP24TSSC0 Скачать руководство пользователя страница 4

Manual version: 6PW105-20190725 

BOM: 3123A1M0

 

iv 

Figure 2 Installing the module 

 

 

5.2  

Removing the module 

1. 

Use a Phillips screwdriver to loosen the captive screws on the module until all pressure is 
released. 

2. 

Simultaneously open the ejector levers of the module to separate the module from the 
backplane, and pull the module slowly out of the slot along the guide rails. 

3. 

Place the module on an anti-static workbench or put it in an anti-static bag, with the component 
side facing up. 

4. 

If you are not to install a new module, install a filler panel in the slot to prevent dust and ensure 
good ventilation in the device. 

 

 

Copyright © 2019 New H3C Technologies Co., Ltd. 

The information in this document is subject to change without notice. 

 

Содержание SecPath NSQM2GP24TSSC0

Страница 1: ...of providing security for 100G networks 3 Specifications Figure 1 Front panel 1 1000BASE X SFP fiber port LEDs 2 10GBASE R SFP fiber port LEDs 3 10GBASE R SFP fiber ports 4 1000BASE X SFP fiber ports 5 Ejector lever 6 Captive screw IMPORTANT Before installing the module you must remove the protection cover from the module Table 1 Module specifications Item Specification Dimensions H W D 40 1 399 2...

Страница 2: ...0BASE X SFP fiber ports and 10GBASE R SFP fiber ports Module Central wavelength nm Connector type Cable specifications Maximum transmission distance SFP GE SX MM850 A 850 LC 50 125 µm MMF 550 m 0 34 miles 62 5 125 µm MMF 275 m 0 17 miles SFP GE LX SM1310 A 1310 LC 9 125 µm SMF 10 km 6 21 miles 50 125 µm MMF 550 m 1804 46 ft 62 5 125 µm MMF 550 m 1804 46 ft SFP GE LH40 SM1310 1310 LC 9 125 µm SMF 4...

Страница 3: ...esent on the port Off No link is present on the port 5 Installing and removing the module CAUTION Wear a reliably grounded ESD wrist strap or ESD gloves when installing or removing the module Do not touch the components on the module 5 1 Installing the module 1 Face the front panel of the device Remove the filler panel from the target slot This example uses slot 2 2 Place the module on a flat surf...

Страница 4: ... separate the module from the backplane and pull the module slowly out of the slot along the guide rails 3 Place the module on an anti static workbench or put it in an anti static bag with the component side facing up 4 If you are not to install a new module install a filler panel in the slot to prevent dust and ensure good ventilation in the device Copyright 2019 New H3C Technologies Co Ltd The i...

Отзывы: