Table 5 Installation tools 

Picture 

Name 

Description 

 

T25 Torx screwdriver 

Installs or removes screws inside chassis ears. A 
flathead screwdriver can also be used for this purpose. 

T15 Torx screwdriver 
(shipped with the server) 

Installs or removes the screw on the access panel. 

T10 Torx screwdriver 
(shipped with the server) 

Installs or removes screws on riser card blanks. 

Flat-head screwdriver 

Installs or removes the system battery. 

 

Cage nut insertion/extraction 
tool 

Inserts or extracts the cage nuts in rack posts. 

 

Diagonal pliers 

Clips insulating sleeves. 

 

Tape measure 

Measures distance. 

 

Multimeter 

Measures resistance and voltage. 

 

ESD wrist strap 

Prevents ESD when you operate the server. 

 

Antistatic gloves 

Prevents ESD when you operate the server. 

 

Antistatic clothing 

Prevents ESD when you operate the server. 

 

Ladder 

Supports high-place operations. 

Содержание SecCenter CSAP-SA

Страница 1: ...H3C SecCenter CSAP SA Installation Guide New H3C Technologies Co Ltd http www h3c com Document version 5W100 20220329...

Страница 2: ...espective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be accur...

Страница 3: ...ce with actual values Square brackets enclose syntax choices keywords or arguments that are optional x y Braces enclose a set of required syntax choices separated by vertical bars from which you selec...

Страница 4: ...presents a generic network device such as a router switch or firewall Represents a routing capable device such as a router or Layer 3 switch Represents a generic switch such as a Layer 2 or Layer 3 sw...

Страница 5: ...ardware model configuration or software version It is normal that the port numbers sample output screenshots and other information in the examples differ from what you have on your device Documentatio...

Страница 6: ...1 Installing rails 1 Rack mounting the server 1 Installing cable management brackets 2 Connecting external cables 2 Cabling guidelines 2 Connecting a mouse keyboard and monitor 2 Connecting an Etherne...

Страница 7: ...ffle 7 Installing the chassis air baffle 7 Replacing a PCIe network adapter 8 Replacing a fan 10 Removing a fan 10 Installing a fan 11 Verifying the installation 11 Replacing a DIMM 12 Replacing the s...

Страница 8: ...any circumstances The surface or component might be hot and present burn hazards WARNING To avoid being burnt allow hot surfaces or components to cool before touching them The server or component is...

Страница 9: ...use the power cords that came with the server Do not use the power cords that came with the server for any other devices Power off the server when installing or removing any components that are not ho...

Страница 10: ...tools Use a portable field service kit with a folding static dissipating work mat Cooling performance Poor cooling performance might result from improper airflow and poor ventilation and might cause...

Страница 11: ...erature higher than 60 C 140 F Do not disassemble crush puncture short external contacts or dispose of the battery in fire or water Dispose of the battery at a designated facility Do not throw the bat...

Страница 12: ...e 1 Airflow direction of the server 1 to 4 Directions of the airflow into the chassis and power supplies 5 to 7 Direction of the airflow out of the chassis 8 Direction of the airflow out of the power...

Страница 13: ...Dust particles 5 m 3 x 10 4 particles m 3 No visible dust on desk in three days Dust suspension 75 m 0 2 mg m 3 Dust sedimentation 75 m to 150 m 1 5 mg m 2 h Sand 150 m 30 mg m 3 The equipment room mu...

Страница 14: ...nstalls or removes screws on riser card blanks Flat head screwdriver Installs or removes the system battery Cage nut insertion extraction tool Inserts or extracts the cage nuts in rack posts Diagonal...

Страница 15: ...4 Picture Name Description Interface cable such as an Ethernet cable or optical fiber Connects the server to an external network Monitor Displays the output from the server...

Страница 16: ...with the rails Rack mounting the server 1 Slide the server into the rack For more information about how to slide the server into the rack see the installation guide for the rails Figure 2 Rack mountin...

Страница 17: ...of the fan modules heatsinks GPUs and PSUs To easily identify ports and connect disconnect cables make sure the cables do not cross Label the cables for easy identification of the cables Wrap unused...

Страница 18: ...plug 3 Connect the mouse and keyboard For a USB mouse and keyboard directly connect the USB connectors of the mouse and keyboard to the USB connectors on the server For a PS2 mouse and keyboard inser...

Страница 19: ...e replacing the Ethernet cable make sure the new cable is the same type or compatible with the old cable 3 Label the Ethernet cable by filling in the names and numbers of the server and the peer devic...

Страница 20: ...compatibility purchase H3C certified USB devices Procedure 1 Optional Remove the access panel if you need to connect the USB device to an internal USB connector For information about how to remove the...

Страница 21: ...d plug into the power receptacle of a power supply at the rear panel as shown in Figure 8 Figure 8 Connecting the power cord 2 Connect the other end of the power cord to the power source for example t...

Страница 22: ...power cord through the opening in the cable clamp and then close the cable clamp as shown by callouts 1 2 3 and 4 in Figure 10 Figure 10 Securing the AC power cord c Slide the cable clamp forward unt...

Страница 23: ...using cable straps You can secure cables to either left slide rails or right slide rails As a best practice for cable management secure cables to left slide rails When multiple cable straps are used...

Страница 24: ...facing outside of the slide rail Figure 13 Securing cables to a slide rail Removing the server from a rack 1 Power down the server For more information see Powering off the server 2 Disconnect all per...

Страница 25: ...the cable management bracket 4 Extend the server from the rack a Open the latches of the chassis ears b Loosen the captive screws c Slide the server out of the rack Figure 16 Extending the server fro...

Страница 26: ...security bezel if any For more information see Removing the security bezel 2 Press the latch on the drive blank inward with one hand and pull the drive blank out of the slot Figure 17 Removing the dr...

Страница 27: ...to verify that the drive is operating correctly For more information see drive LEDs in Appendix B Component specifications Installing power supplies Guidelines The power supplies are hot swappable Ma...

Страница 28: ...o verify that the power supply is operating correctly Installing a PCIe network adapter Procedure 1 Power off the server For more information see Powering off the server 2 Remove the server from the r...

Страница 29: ...Installing a PCIe network adapter to the riser card 6 Install the riser card to the server Insert the riser card onto the PCIe riser connector along the guide rails Figure 25 Installing the riser card...

Страница 30: ...or to DIMM slots A5 through A8 and populate DIMM slots A5 through A8 prior to DIMM slots A9 through A12 Populate DIMM channels in sequence If only one processor is installed start with the lowest numb...

Страница 31: ...For more information see Rack mounting the server 9 Connect the power cord For more information see Connecting the power cord 10 Power on the server For more information see Powering on the server Ve...

Страница 32: ...on about the position of the system power LED see LEDs and buttons in Appendix A Server specifications Powering on the server from the HDM Web interface 1 Log in to HDM For information about how to lo...

Страница 33: ...hod only when the server system crashes For example a process gets stuck 1 Press and hold the power on standby button until the system power LED turns into steady amber 2 Disconnect all power cords fr...

Страница 34: ...rity bezel and then release the latch as shown by callouts 2 and 3 in Figure 27 3 Pull the right edge of the security bezel out of the groove in the right chassis ear to remove the security bezel as s...

Страница 35: ...y is used across all drives in the RAID Back up drive data before replacement If the installed drive contains RAID information you must clear the information before configuring RAIDs As a best practic...

Страница 36: ...Replacing the access panel WARNING To avoid bodily injury from hot surfaces allow the server and its internal modules to cool before touching them Removing the access panel 1 Power off the server For...

Страница 37: ...a Place the access panel on top of the server chassis with the guide pin in the chassis aligned with the pin hole in the locking lever area as shown by callout 1 b Close the locking lever as shown by...

Страница 38: ...can replace a power supply without powering off or removing the server from the rack Procedure 1 Power off the server For more information see Powering off the server 2 Remove the server from the rac...

Страница 39: ...he power supply in slot 2 6 Mount the server in the rack For more information see Rack mounting the server 7 Connect the power cord For more information see Connecting the power cord 8 Power on the se...

Страница 40: ...ing the server from a rack 3 Remove the access panel For more information see Removing the access panel 4 Remove the chassis air baffle Hold the air baffle by the blue notches at both ends and lift th...

Страница 41: ...n the server For more information see Powering on the server Replacing a PCIe network adapter Procedure 1 Power off the server For more information see Powering off the server 2 Remove the server from...

Страница 42: ...er and then pull the PCIe network adapter out of the slot Figure 38 Removing the PCIe network adapter from the riser card 6 Install a new PCIe network adapter to the riser card Insert the network adap...

Страница 43: ...in a correct state Replacing a fan WARNING To avoid bodily injury from hot surfaces allow the server and its internal modules to cool before touching them Removing a fan The fans are hot swappable If...

Страница 44: ...access panel For more information see Installing the access panel 3 Rack mount the server For more information see Rack mounting the server 4 Connect the power cord For more information see Connectin...

Страница 45: ...nstalling DIMMs 7 Install the chassis air baffle For more information see Installing the chassis air baffle 8 Install the access panel For more information see Installing the access panel 9 Rack mount...

Страница 46: ...lays the correct date and time you might need to replace the battery NOTE The BIOS will restore to the default settings after the replacement You must reconfigure the BIOS to have the desired settings...

Страница 47: ...re it into place as shown by callout 2 Figure 45 Installing the system battery 2 Install the removed PCIe modules 3 Install the access panel For more information see Installing the access panel 4 Rack...

Страница 48: ...Product serial number Product model and name Snapshots of error messages and descriptions Hardware change history including installation replacement insertion and removal of hardware Third party soft...

Страница 49: ...ndix B Component specifications 8 Drives 8 Drive numbering 8 Drive LEDs 8 Processor 9 DIMM 9 DRAM DIMM rank classification label 9 DIMM specifications 10 HDDs and SSDs 10 Riser card 11 PCIe network ad...

Страница 50: ...em Specifications Dimensions H W D Without a security bezel 87 5 445 4 748 mm 3 44 17 54 29 45 in With a security bezel 87 5 445 4 769 mm 3 44 17 54 30 28 in Max weight 27 33 kg 60 25 lb Front panel F...

Страница 51: ...tus Ethernet port LED Steady green A link is present on the port Flashing green 1 Hz The port is receiving or sending data Off No link is present on the port Power on standby button and system power L...

Страница 52: ...mouse USB optical drive for operating system installation Rear panel Rear panel view Figure 4 Rear panel components 1 PCIe slots 1 through 3 from the top down processor 1 2 PCIe slots 4 through 6 fro...

Страница 53: ...shing blue 1 Hz The firmware is being updated or the system is being managed by HDM 4 Hz HDM is restarting To restart HDM press the UID button LED for 8 seconds Off UID LED is not activated Power supp...

Страница 54: ...oard or mouse USB optical drive for operating system installation VGA connector DB 15 Connects a display terminal such as a monitor or KVM device BIOS serial port DB 9 The BIOS serial port is used for...

Страница 55: ...ports 11 Front I O connector 12 Optical SATA port 13 Diagnostic panel connector not supported 14 Front drive backplane power connector 1 15 Dual internal USB 3 0 connectors 16 Front drive backplane A...

Страница 56: ...ver startup Pins 2 3 jumped Clears all passwords from the BIOS at server startup To clear all passwords from the BIOS jump pins 2 and 3 and then start the server All the passwords will be cleared from...

Страница 57: ...UID LED 2 Present Active LED Table 6 Drive LED description Fault UID LED status Present Active LED status Description Flashing amber 0 5 Hz Steady green Flashing green 4 0 Hz A drive failure is predi...

Страница 58: ...ns Model Base frequency GHz Power W Cores L3 cache MB UPIs and speed GT s 4110 2 1 85 8 11 2 9 6 NOTE The server comes with one 4110 processor DIMM DRAM DIMM rank classification label A DIMM rank is a...

Страница 59: ...R4 xx or PC4 xx format In DDR4 xx format DDR4 represents the generation and xx represents the data rate in MHz In PC4 xx format PC4 represents the generation and xx represents the bandwidth in MB s DI...

Страница 60: ...4T SATA 6G LFF HDDs No SSDs are provided by default You can purchase SSDs as needed Riser card Figure 12 Riser card view 1 PCIe slot 1 4 2 PCIe slot 2 5 3 PCIe slot 3 6 NOTE If a riser card can be ins...

Страница 61: ...cations Item 800W power supply 550W power supply Model PSR800 12A A PSR550 12A A Rated input voltage range 100 VAC to 240 VAC 50 60Hz 10 A receptacle 192 VDC to 288 VDC 240 HVDC power source 100 VAC t...

Страница 62: ...er supply 550W power supply Cold backup Yes Yes NOTE The server comes with one 550 W power supply 1 1 redundancy and power supply hot swapping are available only when two power supplies of the same mo...

Страница 63: ...art or restart the server from a remote console To start the server from a remote console click Power Power On or the icon To restart the server from a remote console click Power Force System Reset 3...

Страница 64: ...igure 15 Figure 15 BIOS Setup utility Configuring the memory mode from the BIOS 1 Enter the BIOS setup utility 2 Access the IntelRCSetup Memory Configuration Memory RAS Configuration screen 3 Select a...

Страница 65: ...default memory rank sparing is disabled You cannot enable memory rank sparing and the mirror mode at the same time If you set the RAS mode to mirror enabling memory rank sparing restores the default...

Страница 66: ...two ranks are available for each channel By default the Auto mode is used If the number of ranks cannot meet the requirement the system changes the spare rank sparing value to Auto automatically Figu...

Страница 67: ...network port address HDM Shared IPv4 and dedicated network port address HDM Dedicated IPv4 Signing in to HDM 1 Open the browser and enter the HDM management IP address in the https HDM_ip_address for...

Страница 68: ...6 Figure 20 HDM sign in page...

Страница 69: ...pping A module that supports hot swapping a hot swappable module can be installed or removed while the server is running without affecting the system operation K KVM A device that allows remote users...

Страница 70: ...g Unit GUI Graphical User Interface H HBA Host Bus Adapter HDD Hard Disk Drive HDM Hardware Device Management I IDC Internet Data Center K KVM Keyboard Video Mouse L LFF Large Form Factor LRDIMM Load...

Страница 71: ...ta Correction SDS Secure Diagnosis System SFF Small Form Factor SSD Solid State Drive T TCM Trusted Cryptography Module TPM Trusted Platform Module U UEFI Unified Extensible Firmware Interface UID Uni...

Отзывы: