9
Mounting bracket
installation position
Chassis rail
installation position
Distance between the front and
rear rack posts
Power module-side
position
Position c
506 to 648 mm (19.92 to 25.51 in)
Position d
506 to 713 mm (19.92 to 28.07 in)
Position e
531 to 778 mm (20.91 to 30.63 in)
b.
Use the provided M4 screws to attach the chassis rails to the chassis (recommended torque:
12 kgf-cm).
Figure 8 Attaching a mounting bracket and chassis rail to the switch (port-side mounting
position for the mounting brackets)
Figure 9 Attaching a mounting bracket and chassis rail to the switch (power module-side
mounting position for the mounting brackets)
Connecting the grounding cable to the chassis
CAUTION:
The primary grounding point and auxiliary grounding point are located on the left panel of the
chassis. Use one of the grounding points as required. Connect the grounding cable to a grounding
point before you mount the switch in the rack.
The grounding screws provided with the switch are applicable to both the primary and auxiliary
grounding points. This procedure uses the primary grounding point as an example.
To connect the grounding cable:
1.
Unpack the grounding cable and grounding screws.
a
b
c
d
e