H3C S9500E LSR1FW2A1 Скачать руководство пользователя страница 2

Manual version: 6PW102-20150210 

BOM: 3123A0A5

 

ii 

Table 1 Card specifications 

Item Specification 

CF card 

One CF card slot, 256MB by default for the external CF card  
256 MB, 512 MB, or 1 GB for an optional external CF card 

Dimensions (H × W × D) 

40.1 × 400 × 380 mm (1.58 × 15.74 × 14.96 in) 

Power consumption 

85 W to 104 W 

Weight 

3.6 kg (7.94 lb) 

Hot swapping 

Supported 

Ports 

 

1 console port 

 

2 USB ports (reserved for future use) 

 

2 pairs of combo ports, each pair containing the following ports:  

{

 

1 x 10/100/1000BASE-T copper port 

{

 

1 x 1000BASE-X SFP fiber port 

You can use the 

combo

 

enable

 { 

copper

 | 

fiber 

} command to activate either of 

the ports in a pair. By default, the copper combo port is activated. 

Ambient temperature 

 

Operating: 0°C to 45°C (32°F to 113°F) 

 

Not operating: –40°C to +70°C (–40°F to +158°F) 

Ambient relative humidity 

 

Operating: 10% to 95%, noncondensing 

 

Non-operating: 5% to 95%, noncondensing 

Compatible device models   H3C S9500E series switches 

System software version 

See the release notes that come with the card. 

 

Table 2 Console port specifications 

Item Specification 

Connector RJ-45 

Interface standard 

RS-232 

Transmission baud rate 

9600 bps (default) to 115200 bps 

Transmission medium 

Asynchronous serial cable 

Transmission distance 

15 m (49.21 ft) 

Services 

 

Provides connection to an ASCII terminal. 

 

Provides connection to the serial port of a local or remote PC (through a 
pair of modems) that is running a terminal emulation program. 

 

Supports command line interface (CLI). 

 

Table 3 10/100/1000BASE-T copper port specifications 

Item Specification 

Connector RJ-45 

Interface standard 

802.3, 802.3u, and 802.3ab 

Interface type 

MDI/MDIX autosensing 

Supported cable 

Category-5 (or above) twisted pair cable 

Содержание S9500E LSR1FW2A1

Страница 1: ...CFS 4 Console port CONSOLE 5 USB interface 1 reserved 6 USB interface 2 reserved 7 Management Ethernet interface 1 10 100 1000BASE T 8 Management Ethernet interface 2 10 100 1000BASE T 9 Management Ethernet interface 1 LED LINK 10 Management Ethernet interface 1 LED ACT 11 Management Ethernet interface 2 LED LINK 12 Management Ethernet interface 2 LED ACT 13 Management interface 3 Electrical port ...

Страница 2: ...t operating 40 C to 70 C 40 F to 158 F Ambient relative humidity Operating 10 to 95 noncondensing Non operating 5 to 95 noncondensing Compatible device models H3C S9500E series switches System software version See the release notes that come with the card Table 2 Console port specifications Item Specification Connector RJ 45 Interface standard RS 232 Transmission baud rate 9600 bps default to 1152...

Страница 3: ...km 0 34 miles SFP GE LX SM1310 A 1310 nm LC 9 125 μm single mode optical fiber 10 km 6 21 miles SFP GE LH40 SM1310 1310 nm LC 9 125 μm single mode optical fiber 40 km 24 86 miles SFP GE LH40 SM1550 1550 nm LC 9 125 μm single mode optical fiber 40 km 24 86 miles SFP GE LH70 SM1550 1550 nm LC 9 125 μm single mode optical fiber 70 km 43 5 miles SFP GE LH100 SM1550 1550 nm LC 9 125 μm single mode opti...

Страница 4: ...or remove the card Do not touch the components on the PCB 5 1 Installing the card 1 Locate the slot where you will install the LSR1FW2A1 and remove the blank panel from the position This manual describes installing the LSR1FW2A1 to slot 2 2 Push the module with the components facing upward into the slot along the guide rails until the positioning hole of the module is seated onto the positioning p...

Страница 5: ...re not going to install a new card install a filler panel to prevent dust and ensure good ventilation in the switch 6 Logging in to the card The card uses an independent operating system Before you can configure the card you must log in to the card by using one of the following methods Log in from the switch s CLI through the oap connect command Log in through the card s Web interface console port...

Страница 6: ...e a successful card upgrade H3C recommends that you upgrade the card through the card s console port or management Ethernet port For more information about software upgrade of the card see the release notes that come with the card 8 Obtaining documentation To access the most up to date H3C product documentation on the World Wide Web at http www h3c com 1 Go to http www h3c com Technical_Documents ...

Отзывы: