Follow these guidelines when you install or remove a fan tray:

在安装

/

拆卸风扇模块时,请注意如下事项:

Make sure the airflow direction of the fan tray is as required by the installation site.

请确认风扇模块气流方向和安装环境的通风要求一致。

The switch comes with the fan tray slots empty. Before powering on the switch, install a fan tray in 
each fan tray slot and make sure the installed fan trays are the same model.

交换机出厂时风扇插槽均为空,为保证设备的正常散热,用户必须满配相同型号的风扇模块,

否则禁止交换机上电运行。

If more than one fan tray fails during switch operation, do not remove these fan trays 
simultaneously. Replace one fan tray at a time and the replacement of each fan tray cannot take 
more than three minutes.

在交换机运行过程中,如果有多个风扇模块出现故障,在更换风扇模块过程中禁止同时拔出多个风

扇模块,应按照拔出一个立即更换一个的方式进行,且单个风扇模块的更换时间不能超过

3

分钟。

Install a fan tray 

安装风扇模块

Remove a fan tray 

拆卸风扇模块

1

1

2

LSPM1FANSA

LSPM1FANSB

Airflow direction of the switch

交换机的风向设计

Make sure the air inlet and outlet vents are not blocked and the installation site has a good ventilation 

system. 

请确保交换机的进、出风孔不被遮挡,并将交换机安装在具有良好通风散热系统的环境中。

You can provide airflow for the switch from the port side to the power module side or from the power 
module side to the port side by installing different fan trays. 

通过配置不同的风扇模块,可提供“端口侧到电源侧”和“电源侧到端口侧”两种气流方向,满足不
同环境下的散热要求。

The LSPM1FANSA blow air from the power module side to the port side.
The LSPM1FANSB draw air from the port side to the power module side.

LSPM1FANSA

为吹风风扇,风向为电源侧进风,端口侧出风;

LSPM1FANSB

为抽风风扇,风向为端口侧进风,电源侧出风。

Installing and removing a fan tray 

安装

/

拆卸风扇模块

Install and remove a power module

电源模块的安装与拆卸

Installing and removing a power module 

安装

/

拆卸电源模块

1

Available power modules vary by device model, but the installation and removal procedures are the 
same. The following uses the PSR250-12A as an example. To remove a power module, first remove 
the power cord. 

各款交换机支持的电源模块不同,但安装与拆卸方式相似,此处以安装

PSR250-12A

电源模块为例示意。

For power modules available for the switch, see

 H3C S6860 Switch Series Installation Guide

.

各款交换机支持的电源模块型号,请参见《

 H3C S6860

系列以太网交换机 安装指导》。

Make sure the airflow direction of the power module is as required by the installation site.
Do not install power modules with different airflow directions on the same switch. 

请确认电源模块气流方向和安装环境的通风要求一致。不同气流方向的电源模块不要混插在同一台交换
机上。

!

Install a power module

安装电源

Remove a power module

拆卸电源

To remove a DC power cord, you must first use a 
screwdriver to loosen the captive screws on the power 
cord connector.For a PSR450-12D power module, use 
a flat-head screwdriver to loosen the captive screws 
on the connector, and then remove the power cord 
connector from the power module.

需要注意的是,在拆除

PSR450-12D

电源模块时,要先

拆除直流电源插头。

PSR450-12D

电源模块需要先使用

一字螺丝刀逆时针拧下直流电源线插头两侧自带的螺
钉,然后将插头向外拔出。

For a PSR450-12AHD power module, release the jaw 
of the cable clamp and open the cable clamp, and then 
remove the power cord connector from the power 
module. 

PSR450-12AHD

电源模块需要先解开防脱线扣上的卡

扣,然后松开电源线缆上的防脱线扣,最后向外拔出电
源线插头。

2

1

2

1

3

1