1-7
Item
LS-6850-56HF/LS-6850-
56HF-H1/S6850-56HF-S
AN
LS-6850-56HF-H3
S6850-2C
LSWM124XG2QL
modules: 1150 BTU/hr
•
With two
LSWM124TG2H
modules: 1436 BTU/hr
•
With two LSWM116FC
modules: 1314 BTU/hr
Heat dissipation
Heat
dissipation
method
Air cooling
Ventilation
aisles
Front-to-rear or rear-to-front (based on the installed fan trays)
Reliability and availability
Power
module
redundancy
1+1 redundancy
1+1 redundancy
1+1 redundancy
Fan
redundancy
4+1 redundancy
3+1 redundancy
4+1 redundancy
Hot swapping
Power modules and fan trays support hot swapping
Expansion modules support hot swapping, but do not hot swap an expansion module when
the device is starting up
Mean Time
Between
Failure
(MTBF) (year)
LS-6850-56HF/LS-6850-56
HF-H1: 33.2
S6850-56HF-SAN: 54.9
78.7
34
Mean time to
repair (MTTR)
(hour)
LS-6850-56HF/LS-6850-56
HF-H1: 1
S6850-56HF-SAN: 0.5
0.5
1
Availability
LS-6850-56HF/LS-6850-56
HF-H1: 99.999666%
S6850-56HF-SAN:
99.999894%
99.999927%
99.999664%
Environment specifications
Sound
pressure level
at 27°C
(80.6°F)
62.1 dB(A)
65.5 dB(A)
61.3 dB(A)
Altitude
–60 m to +5000 m (–196.85 ft to +16404.20 ft)
Operating
temperature
0°C to 45°C (32°F to 113°F)
Note:
The allowed maximum temperature decreases by 0.33 °C (32.59°F) as the altitude
increases by 100 m (328.08 ft) from 0 m (0 ft).
With the LSWM124XG2Q and LSWM124XG2QL interface module installed on the switch, if
you use an SFP-XG-LH80-SM1550 transceiver module, the operating temperature must be
in the range of 0°C to 40°C (32°F to 104°F).
Storage
–40°C to +70°C (–40°F to +158°F)