Correctly connecting the switch grounding cable is crucial to lightning protection and EMI protection.

交换机地线的正确连接是交换机防雷、防干扰的重要保障,请使用设备随机提供的保护地线正确接地。

!

Ground the switch

安装地线到交换机

2

Use the primary grounding point at the power 
module side 

使用主接地点

 (

靠近电源侧

)

接地

Use the auxiliary grounding point at the 
port side 

使用备用接地点

 (

靠近端口侧

)

接地

Install the switch in a 19-inch rack 

安装交换机到

19

英寸机柜

3

Before installing cage nuts, mark their installation positions on the rack posts.

安装浮动螺母前,建议用户先使用记号笔在机柜立柱上标注浮动螺母安装位置。

3

Attaching the mounting brackets and chassis rails of rack-mount rail kit B to the switch 
(applicable only to an LS-6800-54QF-H3 switch)

挂耳与超短滑道的导轨配合安装(只适用于

LS-6800-54QF-H3

的机型)

Install a mounting bracket (near the power module 
side) and a chassis rail (narrow-spacing installation)

挂耳安装到靠近电源侧、超短滑道的导轨正向安装

Install a mounting bracket (near the port side) and 
a chassis rail (wide-spacing installation) 

挂耳安装到靠近端口侧、超短滑道的导轨反向安装

Attach cage nuts to the rack posts.

安装浮动螺母到机柜方孔条上

Attach slide rails to the rack posts.

安装滑道到机柜

Mounting brackets near the port side  

挂耳安装在靠近端口侧

Mount the switch in the rack (two options)

安装交换机到机柜(二选一)

以产品代码为

LS-6800-54QF-H3

的机型为例

Mounting brackets near the power module side  

挂耳安装在靠近电源侧

To use rack-mount rail kit A or C for rack-mounting the switch, make sure the front ends of the long 
slide rails or slide rails reach out of the chassis rails. To use rack-mount rail kit B for rack-mounting the 
switch, make sure the super-short slide rails slide a minimum length of 90 mm (3.54 in) into the 
chassis rails. 

为保证设备安装后的稳定性,使用长滑道或滑道和配套的导轨安装完成后,请确保长滑道

或滑道的头部露出导轨。使用超短滑道和配套的导轨安装完成后,请确保超短滑道头部进入导轨的最小

深度为

90mm

Connect the other end of the grounding 
cable to the grounding point on the rack

接地线另一端连接到机柜接地点

Connect the other end of the grounding 
cable to the grounding point on the rack

接地线另一端连接到机柜接地点

Airflow direction of the switch

交换机的风向设计

Make sure the air inlet and outlet vents are not blocked and the installation site has a good 
ventilation system. 

请确保交换机的进、出风孔不被遮挡,并将交换机安装在具有良好通风散热系统的环境中。

You can provide airflow for the switch from the port side to the power module side or from the power 
module side to the port side by installing different fan trays. 

通过配置不同的风扇模块,可提供“端口侧到电源侧”和“电源侧到端口侧”两种气流方向,满足不

同环境下的散热要求。

The LSWM1FANSC and LSPM1FANSA blow air from the power module side to the port side. The
LSWM1FANSCB and LSPM1FANSB draw air from the port side to the power module side.
LSWM1FANSC

LSPM1FANSA

为吹风风扇,风向为电源侧进风,端口侧出风;

LSWM1FANSCB

LSPM1FANSB

为抽风风扇,风向为端口侧进风,电源侧出风。

4

1

2

3

3

4

4