Installing the switch 

Installation flow 

Figure 2

 

Installation flow 

 

 

Connect the grounding cable

Install the switch to a 

specified position

Start

Connect the power cord

Verify the installation

Power on the switch

Select and install power modules 

Hot swappable power 

modules are used?

Yes

No

Correctly operating?

Power off the switch

Troubleshoot the switch

No

Yes

Install hot swappable 

components?

Install a PoE module

Install an interface card

Install an OAP card

Select hot swappable 

components

Yes

Correctly operating?

Troubleshoot the switch

Verify the installation

Yes

No

End

No

Hot swappable fan 

trays are used?

Select and install 

fan trays

Yes

No

Fan trays have

 been installed?

No

Yes

Содержание s5800 series

Страница 1: ...H3C S5800 Series Ethernet Switches Quick Start Hangzhou H3C Technologies Co Ltd http www h3c com Document version 6PW109 20140516...

Страница 2: ...d All other trademarks that may be mentioned in this manual are the property of their respective owners Notice The information in this document is subject to change without notice Every effort has bee...

Страница 3: ...rking with the S5800 series Conventions This section describes the conventions used in this documentation set Convention Description WARNING An alert that calls attention to important information that...

Страница 4: ...s Technical Documents Provides hardware installation software upgrading and software feature configuration and maintenance documentation Products Solutions Provides information about products and tech...

Страница 5: ...itions 5 Installing an S5800 54S switch in a 19 inch rack 6 Installing an S5800 60C PWR switch in a 19 inch rack 9 Installing the other S5800 switch models in a 19 inch rack 11 Mounting the switch on...

Страница 6: ...software loading and upgrading and troubleshooting see H3C S5800 Switch Series Installation Guide Product overview The H3C S5800 Switch Series includes the following models S5800 56C S5800 56C PWR S5...

Страница 7: ...e life of your switch install it in an environment that meets the temperature humidity and electromagnetic shield EMS requirements For more information see H3C S5800 Switch Series Installation Guide I...

Страница 8: ...es Hot swappable power modules are used Yes No Correctly operating Power off the switch Troubleshoot the switch No Yes Install hot swappable components Install a PoE module Install an interface card I...

Страница 9: ...ded rack as shown in Figure 3 Figure 3 Attaching an ESD wrist strap Installation accessories All switch models except the S5800 60C PWR switch come with a pair of 1 U mounting brackets The S5800 60C P...

Страница 10: ...ting positions one front mounting position near the network ports one mid mounting position and one rear mounting position near the power modules Figure 6 shows the mounting positions on these switche...

Страница 11: ...ounting brackets to the switch Required For mounting near the power modules see Figure 8 For mounting near the ports see Figure 9 2 Attach chassis rails to the switch Required For mounting near the po...

Страница 12: ...ch has three grounding points as shown in Figure 19 The primary grounding point and auxiliary grounding point 1 are on the right side panel If you use one of these grounding points you must connect th...

Страница 13: ...8 Figure 10 Installing cage nuts in a rack post Figure 11 Installing slide rails to the rack Figure 12 Connecting the grounding cable to the primary grounding point 1 Grounding sign 2 Grounding cable...

Страница 14: ...ks Installation diagram 1 Separate the mounting brackets from cable management brackets Optional See Figure 14 2 Attach the mounting brackets to the switch Required For mounting near the ports see Fig...

Страница 15: ...cable management brackets Figure 14 Attaching mounting brackets to the S5800 60C PWR switch 1 Separate the mounting bracket from the cable management bracket 2 Install mounting brackets near the port...

Страница 16: ...procedure Remarks Installation diagram 1 Attach the mounting brackets to the switch Required See Figure 16 2 Install cage nuts in the rack posts Required See Figure 10 3 Install the switch in the rac...

Страница 17: ...able you can place you switch on a workbench The S5800 54S switch cannot be mounted on a workbench To mount the switch on a workbench 1 Make sure the workbench is clean and correctly grounded 2 Place...

Страница 18: ...have one grounding point at their rear panels The S5800 54S switch has three grounding points as shown in Figure 19 H3C recommends that you use the primary grounding point for the S5800 54S switch Fig...

Страница 19: ...nsert the naked metal part through the black insulation covering into the end of the ring terminal c Secure the metal part of the cable to the ring terminal with a crimper and then cover it with the i...

Страница 20: ...WM1FANSCB Installation Guide Table 4 Installing fan trays Switch model Support for hot swappa ble fan trays Shipped with fan trays Available fan trays Installation diagram S5800 32C No No N A N A S580...

Страница 21: ...16 Figure 22 Installing an LSW1BFAN fan tray Figure 23 Installing an LSW1FAN fan tray Figure 24 Installing an LSWM1FANSC fan tray...

Страница 22: ...PSR300 12D Series Power Modules User Manual H3C LSVM1AC650 LSVM1DC650 Power Modules User Manual H3C LSVM1AC300 LSVM1DC300 Power Modules User Manual and H3C PSR750 A PSR750 D Power Modules User Manual...

Страница 23: ...er module PSR750 A or PSR750 D on the same S5800 60C PWR switch Do not install a PSR750 A power module and a PSR750 D power module on the same S5800 60C PWR switch To install a PSR750 A or PSR750 D po...

Страница 24: ...19 Figure 25 Installing a PSR150 A power module Figure 26 Installing an LSVM1AC650 power module Figure 27 Installing a PSR300 12A power module...

Страница 25: ...A power module If only one power module is installed install the filler panel into another power module slot Figure 30 uses an S5800 54S switch as an example Figure 30 Installing the filler panel on...

Страница 26: ...he power module out with the other hand Figure 31 Removing an LSVM1AC650 power module Connecting the power cord CAUTION Connect the power cord after you install the power module in the switch Make sur...

Страница 27: ...bail latch down to secure the plug to the AC receptacle Figure 32 Installing a bail latch Figure 33 Pulling the bail latch upwards Figure 34 Connecting the AC power cord No bail latch is provided with...

Страница 28: ...nnecting the DC power cord Connecting the DC power cord to a built in power module The DC power cords available for built in power modules are classified as follows 54 VDC RPS power cord which is conn...

Страница 29: ...procedures are the same for the PSR150 D series power module and PSR300 12D series power module Figure 38 uses a PSR300 12D1 power module as an example For the DC power cord connection procedures for...

Страница 30: ...d connector for an LSVM1DC650 LSVM1AC300 power module has tabs To remove the power cord squeeze the tabs on the power cord connector with your thumb and forefinger and then pull the connector out as s...

Страница 31: ...S5800 switch models provide interface card slots For the interface cards available for the switch see H3C S5800 Switch Series Installation Guide You can install interface cards as needed For more inf...

Страница 32: ...is installed The S5800 60C PWR switch provides an OAP card slot and comes with a filler panel in the OAP card slot You can install an OAP card as needed For the OAP cards available for the S5800 60C...

Страница 33: ...t and supports hot swapping of PoE modules You can install an LSW148POEM PoE module on the S5800 60C PWR switch to supply power for powered devices PDs For more information about the LSW148POEM PoE mo...

Отзывы: