background image

 

 

 

 

Grounding the switch

连接保护地线

Correctly connecting the switch grounding cable is crucial to lightning protection and EMI 

protection

.

交换机地线的正确连接是交换机防雷、防干扰的重要保障,请使用设备随机提

供的保护地线正确接地。

To use the grounding point on the rear panel of the chassis, install the grounding cable 

by strictly following the figure below; otherwise, the installation and removal of power 

supplies can be affected. 

选用机箱后面板接地点接地时,请注意按照下面图示角度安装

地线,避免阻碍电源模块的安装和拆卸。

Method 1

Use the ground point on 

the rear panel 

交换机后面板接地

Method 2

Use the ground point on 

the side panel 

交换机侧面板接地

1

2

Connect the grounding cable to the switch

Connect the grounding cable to a grounding strip

Installing a fan tray

安装可插拔风扇

Only the S5500-28SC-HI and S5500-52SC-HI support hot swappable fan trays. 

LSPM1FAN blows air from the power side to port side, and LSPM1FANB draws air from 

the port side to power side. Select a fan tray as needed. 

S5500-28SC-HI

S5500-

52SC-HI

采用可插拔风扇,请您根据安装环境的需要选购合适的风扇:

LSPM1FAN

为吹风

风扇,风向为电源侧进风,端口侧出风;

LSPM1FANB

为抽风风扇,风向为端口侧进风,

电源侧出风。

1

2

1

2

Install

安装

Remove

拆卸

Installing a power module 

安装电源模块

 Method 1 - PSR150-A/PSR150-D/PSR150-A1/PSR150-D1

 Method 2 - PSR360-56A/PSR720-56A/PSR1110-56A

Remove a power module 

拆卸电源模块

1

2

Remove a power module: Press the latch inwards, and 

pull the power module until it is part-way out. Hold the 

handle to pull the power module slowly out of the slot. 

拆卸电源模块:向拉手侧掰动锁闩,同时向外轻微用力
拉出部分电源模块,然后握住拉手拉出整个电源模块。

A PSR1110-56A adds 64 mm (2.52 in) to 
the chassis depth, which includes the depth 
of the power module handle. 

如右图所示,

设备安装PSR1110-56A电源模块后,整机深
度会增加64mm(包含电源模块拉手深度)。

The switch provides one filler panel (filler module) for the power module slot. To prevent 

dust and ensure good ventilation, promptly install a filler panel (filler module) for an 

empty power module slot .

设备随机提供一个电源模块插槽假面板,若电源模块插槽

无须安装电源模块,为防止灰尘进入及保证交换机的正常通风,请及时安装假面板。

Remove a filler panel: Insert a flathead 

screwdriver through the handle and pull the filler 

module outward. 

拆卸假面板:将一字螺丝刀插入

拉手,向外轻微用力拉出假面板

Remove a filler panel 

拆卸假面板

1

2

Install a power module 

安装电源模块

2

Remove a filler panel 

拆卸假面板

Install a power module 

安装电源模块

Отзывы: