Installing the switch in a 19-inch rack
Installation methods
Table 3 Installation methods for the S5130-HI switches
Chassis
Installation
methods
Installation requirements
Installation
procedure
S5130-30S-HI
S5130-54S-HI
S5130-30F-HI
S5130-30C-HI
S5130-34C-HI
S5130-54C-HI
Using front
mounting
brackets
Install the front mounting brackets at the port side or
power module side.
See
"
g by using
front mounting
brackets
."
S5130-30C-PW
R-HI
S5130-54C-PW
R-HI
Using front
and rear
mounting
brackets
•
Install the front mounting brackets at the port
side or power module side.
•
Install the rear mounting brackets according to
the rack depth.
{
If the rack depth is in the range of 429 to 595
mm (16.89 to 23.43 in), orient the bracket
with the wide flange inside the rack.
{
If the rack depth is in the range of 274 to 440
mm (10.79 to 17.32 in) and the distance from
the rear rack posts to the inner surface of the
cabinet door is longer than 153 mm (6.02 in),
orient the bracket with the wide flange
outside the rack.
See
"
g by using
front and rear
mounting
brackets
."
S5130-54QS-HI
Using front
mounting
brackets
Install the front mounting brackets at the power
module side.
See
"
g by using
front mounting
brackets
."
Using front
and rear
mounting
brackets
•
Install the front mounting brackets at the port
side or power module side.
•
Install the rear mounting brackets according to
the rack depth.
{
If the rack depth is in the range of 332 to 496
mm (13.07 to 19.53 in), orient the bracket
with the wide flange inside the rack.
{
If the rack depth is in the range of 174 to 341
mm (6.85 to 13.43 in) and the distance from
the rear rack posts to the inner surface of the
cabinet door is longer than 153 mm (6.02 in),
orient the bracket with the wide flange
outside the rack.
As a best practice, use this method for enterprise
networks.
See
"
g by using
front and rear
mounting
brackets
."
Using front
mounting
brackets and
mounting rail
assemblies
Install the front mounting brackets at the port side or
power module side.
The distance between the front rack post and the rear
rack post must be in the range of 562 to 754 mm
(22.13 to 29.69 in).
As a best practice, use this method for data centers.
See
"
g by using
front mounting
brackets and
mounting rail
assemblies
Содержание S5130-30C-HI
Страница 23: ...16 Figure 20 Mounting the switch in the rack 1 Figure 21 Mounting the switch in the rack 2...
Страница 40: ...33 Figure 46 Installing an expansion card LSWM2SP2PM Figure 47 Installing an expansion card LSPM6FWD 1 2 3 4...
Страница 51: ...44 Figure 57 Connecting the switches in one rack 1 2 3 4 5 6 7 8 9...
Страница 89: ...82 Figure 81 Airflow through the S5130 54C HI switch Figure 82 Airflow through the S5130 54QS HI switch...