9
Rack-mounting by using front mounting brackets
This task requires two people.
This mounting method is applicable only to the S5130-30S-HI, S5130-54S-HI, S5130-30F-HI,
S5130-30C-HI, S5130-34C-HI, S5130-54C-HI, and S5130-54QS-HI switches.
To install the switch in a 19-inch rack by using the front mounting brackets:
1.
Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
2.
Determine the mounting position on the switch for the front mounting brackets.
You can install the front mounting brackets at one of the following positions:
{
S5130-30S-HI, S5130-54S-HI, S5130-30F-HI, S5130-30C-HI, S5130-34C-HI
,
and
S5130-54C-HI switches
—Port side or power module side installation position.
{
S5130-54QS-HI switch
—Power module side installation position.
3.
Attach the front mounting brackets to the chassis:
a.
Unpack the front mounting brackets and the M4 screws (supplied with the switch) for
attaching the brackets to the switch chassis.
b.
Align the round holes in the wide flange of one front mounting bracket with the screw holes
in the chassis.
c.
Use M4 screws to attach the mounting bracket to the chassis.
d.
Repeat the proceeding two steps to attach the other mounting bracket to the chassis.
Figure 8 Attaching the front mounting bracket to the port side
Figure 9 Attaching the front mounting bracket to the power module side
Содержание S5130-30C-HI
Страница 23: ...16 Figure 20 Mounting the switch in the rack 1 Figure 21 Mounting the switch in the rack 2...
Страница 40: ...33 Figure 46 Installing an expansion card LSWM2SP2PM Figure 47 Installing an expansion card LSPM6FWD 1 2 3 4...
Страница 51: ...44 Figure 57 Connecting the switches in one rack 1 2 3 4 5 6 7 8 9...
Страница 89: ...82 Figure 81 Airflow through the S5130 54C HI switch Figure 82 Airflow through the S5130 54QS HI switch...