Operation Manual – Information Center
H3C S3610&S5510 Series Ethernet Switches
Chapter 1 Information Center Configuration
1-6
Note that there is a space between the timestamp and sysname (host name) fields.
III. Sysname
Sysname is the system name of the current host. You can use the
sysname
command
to modify the system name. (Refer to
System Maintaining and Debugging
for details)
Note that there is a space between the sysname and module fields.
IV. Module
The module field represents the name of the module that generates system information.
You can enter the
info-center source ?
command in system view to view the module
list.
Refer to
for module name and description.
Between “module” and “level” is a “/”.
V. Level (Severity)
System information can be divided into eight levels based on its severity, from 0 to 7.
Refer to
for definition and description of these severity levels. Note that there
is a forward slash between the levels (severity) and digest fields.
VI. Digest
The digest field is a string of up to 32 characters, outlining the system information.
Note that there is a colon between the digest and content fields.
VII. Content
This field provides the content of the system information.
1.2 Configuring Information Center
1.2.1 Information Center Configuration Task List
Complete the following tasks to configure information center:
Task
Remarks
Setting to Output System Information to the Console
Optional
Setting to Output System Information to a Monitor Terminal
Optional
Setting to Output System Information to a Log Host
Optional
Setting to Output System Information to the Trap Buffer
Optional
Setting to Output System Information to the Log Buffer
Optional
Setting to Output System Information to the SNMP NMS
Optional