background image

5-3 

Item 

Specifications 

Operating humidity 

5% to 90% 

Maximum altitude 

5000 m (16404.20 ft) 

Redundancy 

Yes 

Cold backup 

Yes 

 

LEDs 

Table4-1 Power supply LED description 

LED status 

Description 

Steady green 

The power supply is operating correctly. 

Flashing green (1 Hz) 

Power is being input correctly but the system is not powered on. 

Flashing green (0.33 Hz) 

The power supply is in standby state and does not output power. 

Flashing green (2 Hz) 

The power supply is updating its firmware. 

Steady amber 

 

The power supply is faulty. 

 

The power supply does not have power input, but the other 
power supply has correct power input. 

Flashing amber (1 Hz) 

An alarm has occurred on the power supply. 

Off 

No power supplies have power input, which can be caused by an 
incorrect power cord connection or power source shutdown. 

 

Installing and removing the power 

supply 

For information about installing and removing the power supply, see the user guide for the device. 

Отзывы: