Verify that the management host can ping the VM. To ensure a successful ping operation, make
sure the firewall of the VM is disabled. By default, the firewall of the VM is disabled. (Details not
shown.)
Configuring the EAD gateway through IMC
About EAD gateway configuration through IMC
After the management host and the EAD gateway become reachable, you can access the IMC Web
interface to configure the EAD gateway through the management host. For more information about
IMC, see user manuals for the H3C Intelligent Management Center in the network management
section of technical documents on H3C websites.
Displaying IMC service running status
The IMC services installed on the VM of the EAD gateway have been set to auto-start when the
gateway is shipped. When the VM starts up, the IMC services also start up.
To view the running status of IMC services and the deployment status of the EAD component:
1.
Right-click the VM desktop and select
Open Terminal
to enter the CLI of the CentOS
shows the CLI.
Figure 15 VM CLI
2.
Open the page that displays IMC services.
[root@localhost~]# cd /opt/iMC/deploy/
[root@localhost~]# ./dma.sh
shows the page that displays IMC services.