To connect the grounding cable for rack-mounting:
1. Connect the building grounding cable to the grounding strip on the rack.
2. Connect one end of the grounding cable to the device and the other end to the
grounding strip on the rack. Make sure the rack is reliably grounded.
Connecting the power cord
Before connecting the power cord, make sure the device is reliably grounded. Make
sure the power switch is off and connect the power cord to the device first and then to
the equipment-room power supply system to avoid bodily injury.
在连接电源线前,需保证设备已正确接地。在连接电源线时,请确认设备电源开关处于关
闭状态,先完成电源线与设备的连接,再进行电源线与机房供电系统的连接,以免造成人
身伤害。
设备安装在机柜时,要求机柜已经良好接地,首先需将楼宇保护地线与机柜接地排相连,然后
使用接地线将设备与机柜接地排相连。
Installing a SIC interface card
SIC
SIC interface cards are not hot swappable.
SIC
接口模块不支持热插拔。
!
To install a SIC interface card:
1. Remove the filler panel from the SIC slot.
2. Insert the SIC interface card.
3. Fasten the captive screws.
安装
SIC
接口模块:拆卸
SIC
槽位假面板,插入
SIC
接口模块,旋紧固定螺钉。