H3C Mini S26 Скачать руководство пользователя страница 7

1. 

Use a Phillips screwdriver to remove the grounding screw from 
grounding hole in the rear panel of the chassis. Use the 
grounding screw to attach the ring terminal of the grounding 
cable to the grounding hole. Fasten the grounding screw into the 
grounding hole. 

2. 

Use needle-nose pliers to make a loop at the other end of the 
cable. 

3. 

Remove the hex nut from a grounding post on the grounding 
strip. Attach the loop to the grounding post and fasten the hex 
nut. 

Figure 5 Connecting the grounding cable 

 

 

Connecting the power cord 

Connecting the AC power cord 

The S26 and S26G switches support AC power input. 

To connect the AC power cord: 

1. 

Make sure the switch is reliably grounded. 

2. 

Connect one end of the AC power cord to the AC power 
receptacle on the switch. 

3. 

Connect the other end of the AC power cord to an AC power 
source. 

Содержание Mini S26

Страница 1: ...in a clean environment Dust buildup on the chassis might result in electrostatic adsorption which reduces lifespan of the device and can cause communication failure Keep the air inlet and outlet vents of the switch free of obstruction and do not stack switches Make sure the operating voltage is in the required range Before using the switch make sure the grounding cable of the switch is correctly c...

Страница 2: ... Workbench mounting Wall mounting S9G Not supported Supported Supported S26 Supported Supported Not supported S26G Supported Supported Not supported Mounting in a 19 inch rack No mounting brackets and screws are provided with the switch Prepare them yourself To install the switch in a 19 inch rack 1 Verify that the rack is reliably grounded and is stable 2 Use screws to attach the mounting bracket...

Страница 3: ...e the switch on a rack shelf in the rack Push the switch in until the oval holes in the brackets align with the mounting holes in the front rack posts 4 Use screws to secure the mounting brackets to the front rack posts Figure 2 Mounting the switch in the rack ...

Страница 4: ...up and clean the four recessed areas in the chassis bottom with a soft and dry cloth 3 Attach the rubber feet to the recessed areas 4 Place the switch upside up on the workbench Mounting on a wall You can use pan head screws and the mounting holes in the switch bottom to mount the switch on a wall No screws and screw anchors are provided with the switch Prepare them yourself The following figure s...

Страница 5: ...hor If you use screws and screw anchors of the recommended size the hole diameter is 5 mm 0 20 in 2 Drill two holes spacing 90 mm 3 54 in on the wall Make sure the two holes are on a horizontal line 3 Fasten a screw anchor into each hole and make sure the anchor is flush with the wall 4 Insert a screw into each anchor leaving a minimum of 2 5 mm 0 10 in between the screw head and wall for mounting...

Страница 6: ...Correctly connecting the grounding cable is crucial to lightning protection and EMI protection The switch is not provided with a grounding cable Prepare one yourself The S9G switch does not have a grounding screw and you do not need to connect a grounding cable for it To connect the grounding cable ...

Страница 7: ...ther end of the cable 3 Remove the hex nut from a grounding post on the grounding strip Attach the loop to the grounding post and fasten the hex nut Figure 5 Connecting the grounding cable Connecting the power cord Connecting the AC power cord The S26 and S26G switches support AC power input To connect the AC power cord 1 Make sure the switch is reliably grounded 2 Connect one end of the AC power ...

Страница 8: ...ove an SFP transceiver module do not touch the golden plating on it Remove the dust plugs from an SFP transceiver module only when you are to connect optical fibers to the module Before installing an SFP module remove the optical fibers if any from it To install an SFP transceiver module and optical fibers 1 Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded ...

Страница 9: ...nnectors of the optical fibers to the transceiver module Figure 7 Installing the optical fibers Accessing the switch The switch supports Web management To access the switch 1 Connect the switch to a PC Make sure the switch and PC are reachable to reach other By default the management IP address of the switch is 192 168 0 233 and the subnet mask is 255 255 255 0 ...

Страница 10: ...e address bar of your browser 3 On the login page that opens enter the user name password and verification code select the language and click Login The default username and password are admin case sensitive Figure 8 Accessing the switch ...

Страница 11: ...11 Appendix A Chassis views and technical specifications Chassis views Front panel Figure 9 S9G front panel Figure 10 S26 front panel 1 2 3 4 5 ...

Страница 12: ... TX copper port status LED 4 1000Base X SFP fiber port status LED 5 100Base X SFP fiber port status LED 6 10 100Base TX copper port 7 10 100 1000Base T copper port 8 100 1000Base X SFP fiber port 9 Reset button 10 100 1000Base X SFP fiber port status LED 11 10 100 1000Base T copper port status LED ...

Страница 13: ...ut 5 seconds until the power LED slowly flashes green Restoring the factory default and rebooting the switch Press the reset button for about 10 seconds until the power LED fast flashes green If you press the reset button for over 15 seconds until the power LED turns steady green the system does not perform any restoring tasks Rear panel Figure 12 S9G rear panel Figure 13 S26 S26G rear panel ...

Страница 14: ...ations Item S9G S26 S26G Dimensions H W D 27 235 105 mm 1 06 9 25 4 13 in 44 330 173 mm 1 73 12 99 6 81 in 44 330 173 mm 1 73 12 99 6 81 in Weight 0 5 kg 1 10 lb 1 5 kg 3 31 lb 1 6 kg 3 53 lb Port 8 10 100 1000Base T copper port 1 100 1000 Base X SFP fiber port 24 10 100Base T X copper port 1 10 100 1000B ase T copper port 1 100 1000Base X SFP fiber port 24 10 100 1000 Base T copper port 2 100 100...

Страница 15: ... 1 A AC 100 VAC to 240 VAC 50 Hz or 60 Hz Connector Fiber port LC Copper port RJ 45 Port transmission rate Fiber port 1000 100 Mbps full duplex Copper port Half full duplex auto negotiation MDI MDI X Overall leakage current GB4943 1 Operating temperature 0 C to 40 C 32 F to 104 F Operating relative humidity 5 RH to 95 RH noncondensing Fire resistance compliance GB4943 1 ...

Страница 16: ...opper port status LED on S26 and S26G switches Link Act Steady green A 1000 Mbps link is present Flashing green The port is receiving or sending data at 1000 Mbps Steady yellow A 10 100 Mbps link is present Flashing yellow The port is receiving or sending data at 10 100 Mbps Off No link is present 10 100 Base TX copper port status LED on the S26 switch Link Act Steady green A 10 100 Mbps link is p...

Страница 17: ...llow A 10 100 Mbps link is present Flashing yellow The port is receiving or sending data at 10 100 Mbps Off No link is present 100 1000 BASE X SFP port status LED Link Act Steady green A 1000 Mbps link is present Flashing green The port is receiving or sending data at 1000 Mbps Steady yellow A 100 Mbps link is present Flashing yellow The port is receiving or sending data at 100 Mbps Off No link is...