![H3C LSPM1CX2P Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/h3c/lspm1cx2p/lspm1cx2p_user-manual_3120541007.webp)
7
until the interface card is in close contact with the switch, as
shown in
.
(4) Tighten the captive screws with a Phillips screwdriver to fix the
interface card.
Figure 5
Install an interface card (II)
Caution:
Keep the removed filler panel properly for future use.
When tightening the fastening screws at both sides of the
interface card with a screwdriver or an electric screwdriver,
make sure that the torque is not bigger than 0.4 N-m.
Removing the interface card
Follow these steps to remove the interface card:
(1) Wear an ESD-preventive wrist strap, and make sure that the
ESD-preventive wrist strap makes good skin contact and is
properly grounded.
(2) Use a Phillips screwdriver to loosen the captive screws at both
sides of the interface card until all spring pressure is released.
(3) Pull the interface card towards you along the guide rails, until it
completely comes out of the switch chassis.