2-30
a.
Hold the pull latch to remove the connector from the PI.
b.
Insert and press down a flathead screwdriver straight into a release slot. This will open the
round-shaped hole below that release slot.
c.
Remove the wire from the connector. Perform step
again to remove the other wire.
d.
Press the red and blue buttons to reset the spring tabs inside the connector.
Figure2-35 Re-wiring a DC power connector
Verifying the installation
After you complete the installation, verify that:
•
There is enough space for heat dissipation around the switch, and the rack or workbench is
stable.
•
The grounding cable is securely connected.
•
The correct power source is used.
•
The power cords are correctly connected.
•
All the interface cables are cabled indoors. If any cable is routed outdoors, verify that the socket
strip with lightning protection and lightning arresters for network ports have been correctly
connected.