30
Table 41 LED description
LED Description
B1
Green
Flashing indicates data is being transmitted or received on B1 channel.
B2
Green
Flashing indicates data is being transmitted or received on B2 channel.
ACT
Yellow
•
Flashing indicates the link is being activated.
•
Steady on indicates the link is active.
ON
Green, power LED.
Steady on indicates the module is powered on.
Interface cables and the connection methods
For more information about BSV interface cables and the connection methods, see "
SIC-1VE1
Introduction
The 1-port E1 voice interface module (SIC-1VE1) can handle dense voice signals in VoIP system. It
provides a CE1/PRI/R2 port, allowing the access of 30 channels of voice signals.
Interface specifications
Table 42 Interface specifications
Item Description
Connector DB
15
Number of connector
1
Interface standard
G.703, G.704
Interface rate
2.048 Mbps
Frame format
•
Ethernet_II
•
Ethernet_SNAP
•
IEEE
802.2
•
IEEE
802.3
Cable type
•
75-ohm unbalanced coaxial cable
•
120-ohm balanced twisted pair cable
•
Coaxial connector, network interface connector and 75-ohm to
120-ohm adapter (with BNC connector)
Operation mode
CE1
ISDN PRI (only supported by SIC-1VE1)
R2