By default, Ethernet interfaces are in the non-synchronous mode. An interface can participate
in the clock reference selection only when it is in the synchronous mode.
4.
Enable ESMC to transmit QL information.
esmc enable
By default, ESMC is disabled on Ethernet interfaces.
Display and maintenance commands for SyncE
Execute
display
commands in any view.
Task Command
Display ESMC information.
display esmc
[
interface
interface-type
interface-number
]
Synchronous Ethernet configuration examples
Example: Configuring synchronous Ethernet
Network configuration
As shown in
, configure SyncE between the devices.
Figure 2 Network diagram
Procedure
# On Device A, enable the synchronous mode and ESMC on Ten-GigabitEthernet 3/1/1.
<DeviceA> system-view
[DeviceA] interface ten-gigabitethernet 3/1/1
[DeviceA-Ten-GigabitEthernet3/1/1] synchronous mode
[DeviceA-Ten-GigabitEthernet3/1/1] esmc enable
[DeviceA-Ten-GigabitEthernet3/1/1] quit
# On Device B, enable the synchronous mode and ESMC on Ten-GigabitEthernet 3/1/1.
<DeviceB> system-view
[DeviceB] interface ten-gigabitethernet 3/1/1
[DeviceB-Ten-GigabitEthernet3/1/1] synchronous mode
[DeviceB-Ten-GigabitEthernet3/1/1] esmc enable
[DeviceB-Ten-GigabitEthernet3/1/1] quit
Verifying the configuration
# Verify that ESMC is enabled on both Device A and Device B when they are connected to their
respective clock references. The clock QLs of Device A and Device B are
QL-PRC
and
QL-SEC
,
respectively. Device A provides more precise timing than Device B.
[DeviceA] display esmc
Interface : Ten-GigabitEthernet3/1/1